نتایج جستجو برای: liner wear

تعداد نتایج: 29732  

2012
Johanna Olofsson T. Mikael Grehk Torun Berlind Cecilia Persson Staffan Jacobson Håkan Engqvist

Many of the failures of total joint replacements are related to tribology, i.e., wear of the cup, head and liner. Accumulation of wear particles at the implants can be linked to osteolysis which leads to bone loss and in the end aseptic implant loosening. Therefore it is highly desirable to reduce the generation of wear particles from the implant surfaces. Silicon nitride (Si(3)N(4)) has shown ...

Journal: :The Journal of bone and joint surgery. British volume 2007
K Knahr M Pospischill P Köttig W Schneider H Plenk

Two Durasul highly crosslinked polyethylene liners were exchanged during revision surgery four and five years after implantation, respectively. The retrieved liners were evaluated macroscopically and surface analysis was performed using optical and electron microscopy. A sample of each liner was used to determine the oxidation of the material by Fourier transform infrared spectroscopy. Samples ...

Journal: :The Journal of arthroplasty 2009
Steven N Shah Rachel J Kaye Natalie H Kelly Edwin P Su Douglas E Padgett Timothy M Wright

Despite the large loads placed upon constrained acetabular liners, little is known of their mechanical performance. We analyzed retrieved liners to determine wear and other damage modes and assess associations between types and severity of damage and clinical, radiographic, and implant variables. Outer rim impingement frequency and severity were higher than that for the inner rim. The 20 degree...

Journal: :Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2006
Jiri Gallo Vitezslav Havranek Ivana Cechova Jana Zapletalova

Periprosthetic osteolysis is associated with accelerated wear rates. The goal of this study was to investigate the influence of demographic and technical variables on wear rates and size of osteolytic lesions. Eighty retrieved ABG I prostheses were analyzed according to prospectively established criteria. There were 22 men and 58 women with an average age of 52 years (34-65) at the time of revi...

Journal: :Canadian journal of surgery. Journal canadien de chirurgie 2000
J P Santerre R S Labow E L Boynton

Aseptic loosening after total joint replacement remains the most common reason for long-term implant failure. Macrophages activated by submicron wear particles of the polyethylene liner used in joint replacement have been shown to be the source of periprosthetic bone loss. Understanding the role of material chemistry in macrophage activation and the subsequent effects that macrophage-derived en...

Journal: :Acta orthopaedica Belgica 2002
S Olesen Schaarup J E Varmarken

Based on a case report in which wear of the polyethylene liner in an uncemented hip prosthesis led to the development of an intrapelvic mass, the pathogenesis, diagnosis and treatment are described. Characteristic osseous and soft tissue reactions caused by release of polyethylene particles to periarticular tissue are discussed as well as the differential diagnosis with infectious and malignant...

Journal: :Canadian journal of surgery. Journal canadien de chirurgie 1997
A E Gross W N Dust

The smaller acetabular components used in total hip replacement may have a polyethylene liner that is too thin, resulting in higher polyethylene stress and an increased potential for wear. The authors present a case that highlights the problem of acute polyethylene fracture. To compensate for the thinness of the polyethylene, the authors recommend the use of a smaller head size to allow polyeth...

2015
Won-Kee Choi Myung-Rae Cho Seung-Bum Chae Dong-Young Kim

It has been known the highly cross linked polyethylene (HXLPE) has an advantage of improved wear rate. However, the alteration in mechanical properties such as decreased tensile yield and fatigue strength make concerns about fragility of HXLPE. We experienced a case of HXLPE breakage. But, this case of liner breakage happened although patient belonged to normal BMI and proper acetabular cup pos...

Journal: :Journal of the mechanical behavior of biomedical materials 2010
Matthew G Teeter Douglas D R Naudie Kory D Charron David W Holdsworth

There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved...

Journal: :Journal of the mechanical behavior of biomedical materials 2018
Behzad Shiroud Heidari Seyed Mohammad Davachi Amin Hedayati Moghaddam Javad Seyfi Iman Hejazi Razi Sahraeian Hamid Rashedi

In this study, injection molding process of ultrahigh molecular weight polyethylene (UHMWPE) reinforced with nano-hydroxyapatite (nHA) was simulated and optimized through minimizing the shrinkage and warpage of the hip liners as an essential part of a hip prosthesis. Fractional factorial design (FFD) was applied to the design of the experiment, modeling, and optimizing the shrinkage and warpage...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید