نتایج جستجو برای: ion chamber dosimetry gamma ray cobalt 60 iec 60731

تعداد نتایج: 951194  

Journal: :Turkish journal of haematology : official journal of Turkish Society of Haematology 2000
A Top M Coşkun T Orta

Development of radiation technology has resulted in increasing numbers of people working with it. Therefore it has increasingly been important to monitor the radiation in order to ensure public safety. Physical dosimetry plays an important role in monitoring. But a need arise for biological dosimetry where physical dosimetry is absent or its presence is insufficient. In this study Co-60 gamma r...

Journal: :iranian journal of radiation research 0
m.a. gadhi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan s.a. buzdar department of physics, the islamia university of bahawalpur, pakistan m. afzal department of physics, the islamia university of bahawalpur, pakistan sh. fatmi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan m.s. akhtar bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan a.h. nizamani department of physics, university of sind, jamshoro, hyderabad, pakistan

background: the effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted standards. secondary standard dosimetry laboratory (ssdl) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192ir . this work has been carried out to calibrate the high dose rat...

A.H. Nizamani, M. Afzal, M.A. Gadhi, M.S. Akhtar, S.A. Buzdar, Sh. Fatmi,

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

2011
Aime M. Gloi Robert E. Buchanan Corrie L. Zuge AnnDrea M. Goettler

The purpose is to devise a patient-specific quality assurance procedure for RapidArc radiotherapy using the MapCHECK detector array. We use our existing MapCHECK system and a Solid Water phantom with an embedded ion chamber to develop a quality assurance procedure for RapidArc treatment after commissioning. The ion chamber used to measure the absolute dose is surrounded by 6 cm layers of solid ...

2010
Md Nurul Amin Robert Heaton Bern Norrlinger Mohammad K. Islam

The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becomin...

2015
Wook Jae Yoo Sang Hun Shin Dong Eun Lee Kyoung Won Jang Seunghyun Cho Bongsoo Lee

We fabricated a small-sized, flexible, and insertable fiber-optic radiation sensor (FORS) that is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA) to obtain the energy spectra of radioactive isotopes. As an inorganic scintillator for gamma-ray spectroscopy, a cerium-doped lutetium yttrium orthosilicate (...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran ghorban safaeian m.sc., in medical physics, mashhad university of medical sciences, mashhad, iran mohammad hosein bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahram baiani m.sc., in medical engineering, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

2015
Jonas O. da Silva Linda V. E. Caldas

The ionization chambers are widely utilized in diagnostic radiology quality control and dosimetry. They are simple to use, and can be found commercially in various types depending on their applications. They are the recommended devices for the determination of the beam qualities in mammographic range. To assure the reliability of the measurements, the stability of the response of the ionization...

Journal: :Physics in medicine and biology 2000
A M Morgan E G Aird R J Aukett S Duane N H Jenkins W P Mayles C Moretti D I Thwaites

United Kingdom dosimetry codes of practice have traditionally specified one electrometer for use as a secondary standard, namely the Nuclear Enterprises (NE) 2560 NPL secondary standard therapy level exposure meter. The NE2560 will become obsolete in the foreseeable future. This report provides guidelines to assist physicists following the United Kingdom dosimetry codes of practice in the selec...

Journal: :Physics in medicine and biology 2014
Joao Seco Ben Clasie Mike Partridge

The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of multi-slice CT and digital x-ray imaging syst...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید