نتایج جستجو برای: intermediate steel moment resisting frame system

تعداد نتایج: 2531399  

2012
Mohammad AlHamaydeh Sherif Yehia Nader Aly Ammar Douba

Four design alternatives for lateral force-resisting systems of tall buildings in Dubai, UAE are presented. Quantitative comparisons between the different designs are also made. This paper is intended to provide different feasible lateral systems to be used in Dubai in light of the available seismic hazard studies of the UAE. The different lateral systems are chosen in conformance with the Inte...

2015
Mehdi Babaei S. Alireza Mousavi

Building structures are subject to displacement under the influence of forces resulting from earthquake. The most common method of controlling such displacements in steel structures, which are usually of lateral type, is the use of braces. Depending on designing requirements and feasibility, braces are available in various forms. Configuration of bracing systems is generally of concentric or ec...

2017
Sudeok Shon Mina Yoo Seungjae Lee

The steel frame reinforced with steel shear wall is a lateral load resisting system and has higher strength and shear performance than the concrete shear wall system. Especially, using corrugated steel plates in these shear wall systems improves out-of-plane stiffness and flexibility in the deformation along the corrugation. In this paper, a cyclic loading test of this steel frame reinforced wi...

Journal: : 2021

According to current design practices of steel moment-resisting frames, formation plastic hinges is unavoidable when the frames are supported by conventional column base systems, i.e., exposed-type and embedded-type due unequalized flexural moment demand on top first story columns [1]. Kimura et.al [3] has proposed mid-story pin system avoid from yielding realize beam-yielding mechanism applyin...

Journal: : 2021

Mid-story pin column system has been proposed to realize beam yielding mechanism of a steel moment-resisting frame. In this system, connection is applied inbetween the upper and lower RC extended from base control moment demands on both ends first story column. An exposed-type adopted as connected by single anchor bolt. Static cyclic horizontal loading tests partial frame consisting second floo...

2015

Abstract—Nowadays, energy dissipation devices are commonly used in structures. High rate of energy absorption during earthquakes is the benefit of using such devices, which results in damage reduction of structural elements, specifically columns. The hysteretic damping capacity of energy dissipation devices is the key point that it may adversely make analysis and design process complicated. Thi...

2015
Kyung - Suk Choi Joon Kim

Modular structural systems are constructed using a method that they are assembled with prefabricated unit modular frames on-site. This provides a benefit that can significantly reduce building construction time. The structural design is usually carried out under the assumption that their load-carrying mechanism is similar to that of traditional steel moment-resisting systems. However, both syst...

Journal: : 2022

When a steel moment-resisting frame deforms horizontally, H-shaped beams are subjected to the flexural moment gradient. Generally, rigidly connected box section columns possessing large fork restraint. Further, continuous braces on top flange effectively prevent lateral buckling. In this paper, buckling behavior of continuously braced with restraint under gradient is clarified theoretically and...