نتایج جستجو برای: heterogeneous slab phantom

تعداد نتایج: 152537  

2011
Jean‐François Aubry Hugo Bouchard Igor Bessières Frédéric Lacroix

The purpose of this study is to validate Eclipse's electron Monte Carlo algorithm (eMC) in heterogeneous phantoms using radiochromic films and EGSnrc as a reference Monte Carlo algorithm. Four heterogeneous phantoms are used in this study. Radiochromic films are inserted in these phantoms, including in heterogeneous media, and the measured relative dose distributions are compared to eMC calcula...

2008
M. Han B. A. Hargreaves

Introduction: For RF-spoiled gradient echo imaging (ie SPGR, FLASH, T1-FFE), the combination of spoiling gradients and quadratic phase cycling eliminates net transverse magnetization within a voxel [1-4] to enable pure T1 contrast. Generally, many RF excitations are required to attain steady state magnetization levels. Therefore, when unsaturated spins are flowing into the imaging volume, inflo...

2011
Françoise Lliso Domingo Granero Jose Perez-Calatayud Vicente Carmona M Carmen Pujades Facundo Ballester

PURPOSE The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of...

2011
C. C. Arwui

The objective of calibrating TLD badges and radiation survey meters demand that accurate dose gets to the TLDs and radiation survey meters. A lead block mould and an ICRU slab phantom had been designed and constructed to collimate the panoramic Cs-137 source at the secondary standards dosimetry laboratory (SSDL) by experts at the National Nuclear Research Institute (NNRI) workshop of the Ghana ...

Journal: :Optics express 2007
Paola Taroni Daniela Comelli Andrea Farina Antonio Pifferi Alwin Kienle

Time-resolved transmittance spectroscopy was performed in the wavelength range of 610 or 700 to 1050 nm on phantom parallelepipeds and bone tissue cubes of different sizes. The data were best fitted with solutions of the diffusion equation for a laterally infinite slab and for a parallelepiped to investigate how size and optical properties of the samples affect the results obtained with the two...

Journal: :European journal of radiology 2012
Christian von Falck Thomas Rodt Stephan Waldeck Dagmar Hartung Bernhard Meyer Frank Wacker Hoen-oh Shin

OBJECTIVES To assess the feasibility of an objective approach for the evaluation of low-contrast detectability in multidetector computed-tomography (MDCT) by combining a virtual phantom containing simulated lesions with an image quality metric. MATERIALS AND METHODS A low-contrast phantom containing hypodense spheric lesions (-20 HU) was scanned on a 64-slice MDCT scanner at 4 different dose ...

Journal: :Applied optics 1996
J C Hebden S R Arridge

A method of generating images through highly scattering media is presented that involves comparing measurements of the time-dependent intensity of transmitted light with an analytical model describing the sensitivity of that intensity on localized changes in optical properties. A least-squares fitting procedure is employed to derive the amplitudes of the measurement perturbations caused by embe...

Journal: :Journal of Applied Clinical Medical Physics 2019

2016
Petra M Härtl Marius Treutwein Matthias G Hautmann Manuel März Fabian Pohl Oliver Kölbl Barbara Dobler

INTRODUCTION A sweeping beam technique for total body irradiation in standard treatment rooms and for standard linear accelerators (linacs) is introduced, which does not require any accessory attached to the linac. Lung shielding is facilitated to reduce the risk of pulmonary toxicity. Additionally, the applicability of a commercial radiotherapy planning system (RTPS) is examined. MATERIAL AN...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید