نتایج جستجو برای: fricke gel dosimeter

تعداد نتایج: 107206  

Journal: :iranian journal of radiation research 0
a.r. farajollahi department of medical physics, faculty of medicine, tabriz university of medical sciences, tabriz, iran f. pak department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran m. horsfield department of cardiovascular sciences, university of leicester, leicester royal infirmary, leicester, uk z. myabi department of radiology, emam reza teaching hospital, tabriz university of medical sciences, tabriz, iran

background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) respons...

Journal: :Journal of Physics: Conference Series 2009

Journal: :iranian journal of radiation research 0
s.m. abtahi shahid beheshti university, nuclear engineering faculty, tehran, iran m. shahriari shahid beheshti university, nuclear engineering faculty, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran h. khalafi nuclear science and technology research institute, tehran, iran sh. akhlaghpoor novin medical radiation institute, tehran, iran s. bagheri novin medical radiation institute, tehran, iran

parameters that have to be measured in gel dosimetry. however, the resolution in gel is strongly dependant on gel composition. selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. materials and methods: magica polymer gel dosimeters were manufactured and irradia...

2001
Yin-Jiun Tseng Woei-Chyn Chu Sung-Cheng Huang

Abstract-A mathematical modeling was adopted to calculate the ferric ion diffusion coefficient based on the radiation induced magnetic resonance (MR) image intensity change in Fricke-agarose gels. A fast magnetic resonance imaging acquisition technique was employed to avoid the smearing of acquired data due to diffusion over an extended period of time. Our results showed that for a Fricke-agaro...

2012
B. Azadbakht

The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...

Journal: :iranian journal of radiation research 0
f. pake department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran a. takavar department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.a. nedaie department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.r. saligheh rad department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran e. eqlimi department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran v. vaezzadeh department of radiotherapy oncology, cancer research centre, cancer institute, tehran university of medical sciences, tehran, iran

background:  in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...

2012
N. Gopishankar S. Vivekanandhan S.S. Kale G.K. Rath S. Senthilkumaran S. Thulkar V. Subramani M.A. Laviraj R.K. Bisht A.K. Mahapatra

This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in...

2011
Timothy Olding Oliver Holmes Paul DeJean Kim B. McAuley Ken Nkongchu Giles Santyr L. John Schreiner

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

R. Jafari Khalilabadi, S. Aftabi, S.M. Abtahi,

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید