2014
Stefano Peca Derek W. Brown

The electronic portal imaging device (EPID) has the potential to be used for in vivo dosimetry during radiation therapy as an additional dose delivery check. In this study we have extended a method developed by A. Piermattei and colleagues in 2006 that made use of EPID transit images (acquired during treatment) to calculate dose in the isocenter point. The extension allows calculation of two-di...

Journal: :iranian journal of radiation research 0
m.a. mosleh-shirazi department of radiotherapy, namazi hospital, shiraz university of medical sciences, shiraz, iran h. taylor department of radiotherapy, royal marsden hospital, sutton, surrey, uk a.p. warrington joint department of physics, royal marsden hospital and institute of cancer research, sutton, surrey, uk f.h. saran department of radiotherapy, royal marsden hospital, sutton, surrey, uk

background: in order to assign appropriate planning target volume (ptv) margins, each centre should measure the patient positioning deviations for their set-up techniques. at the royal marsden hospital, uk, a conformal shell (cast) system is used when a stereotactic frame is not suitable. in this paper, we report on a series of measurements with the aim of obtaining the systematic and random co...

2003
J. I. Prisciandaro M. G. Herman J. J. Kruse

A method to investigate light and radiation field congruence utilizing a commercially available amorphous silicon electronic portal imaging device (EPID) was developed. This method employed an EPID, the associated EPI software, and a diamond-shaped template. The template was constructed from a block tray in which Sn/Pb wires, 1 mm in diameter, were embedded into a diamond shaped groove milled i...

2017
Arpita Agarwal Nikhil Rastogi K. J. Maria Das S. A. Yoganathan D. Udayakumar Shaleen Kumar

PURPOSE With the advent of state-of-the-art treatment technologies, the use of small fields has increased, and dosimetry in small fields is highly challenging. In this study, the potential use of Varian electronic portal imaging device (EPID) for small field measurements was explored for 6 and 15 MV photon beams. MATERIALS AND METHODS The output factors and profiles were measured for a range ...

Journal: :Physics in medicine and biology 2015
Yiannis Roussakis Rongxiao Zhang Geoff Heyes Gareth Webster Suzannah Mason Stuart Green Brian Pogue Hamid Dehghani

The feasibility of real-time portal imaging during radiation therapy, through the Cherenkov emission (CE) effect is investigated via a medical linear accelerator (CyberKnife(®)) irradiating a partially-filled water tank with a 60 mm circular beam. A graticule of lead/plywood and a number of tissue equivalent materials were alternatively placed at the beam entrance face while the induced CE at t...

2015
Travis R. Denton Lisa B.E. Shields Jonathan N. Howe Aaron C. Spalding

A dataset range of isocenter congruency verification tests have been examined from a statistical perspective for the purpose of establishing tolerance levels that are meaningful, based on the fundamental limitation of linear accelerator isocentricity and the demands of a high-precision stereotactic radiosurgery program. Using a laser-defined isocenter, a total of 149 individual isocenter congru...

Journal: :International journal of radiation oncology, biology, physics 2004
Laura Ellen Millender Michele Aubin Jean Pouliot Katsuto Shinohara Mack Roach

PURPOSE We summarize our experience with a series of morbidly obese men treated using daily online portal imaging and implanted gold markers to guide external beam radiation therapy (EBRT). METHODS AND MATERIALS Three consecutive morbidly obese men were treated with EBRT for localized prostate cancer. Daily electronic portal imaging was used to verify patient position. The magnitude and direc...

Ali Asghar Mowlavi, Azam Afzalifar Mohammad Mohammadi, Sara Abdollahi

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

2005
Michael H. Wittmer Thomas M. Pisansky Jon J. Kruse Michael G. Herman

The purpose of this study was to evaluate electronic portal imaging (EPI) as a means of identifying and correcting field displacement in patients with problematic external beam radiotherapy setups. Fourteen patients with problematic setups were identified for pretreatment daily EPI beam monitoring as part of a physician-directed therapist intervention protocol. Pretreatment EPIs were used to re...

2006
Mohammad Mohammadi Eva Bezak Paul Reich

A scanning liquid-filled ionization chamber electronic portal imaging device (SLIC-EPID) and extended dose range (EDR2) films were used to evaluate transmitted dose profiles for homogeneous and inhomogeneous phantoms. Calibrated ionization chamber measurements were used to convert the pixel values acquired from the electronic portal images to dose. Because SLIC-EPID was developed to have a unif...