نتایج جستجو برای: electrode response decay
تعداد نتایج: 1103418 فیلتر نتایج به سال:
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (
In this research, an enzyme modified electrode has been produced during the electropolymerization of aniline through incorporation of sulfite oxidase into a conducting polymer. Then the bioelectrochemical response of resulted sulfite biosensor was investigated at different experimental conditions. Study of the stability of the resulted sulfite biosensor revealed that formation of a passive...
We describe the electrochemical detection of single iridium oxide nanoparticle (IrO(x) NP) collisions on a NaBH(4)-treated Pt ultramicroelectrode (UME). We observe single NP events through the enhanced current by electrocatalytic water oxidation, when IrO(x) contacts the electrode and transiently sticks to it. The overall current transient consists of repeated current spikes that return to the ...
During the electrochemical analysis or disposal of most of phenolic compounds, insulated polymeric substrates are created and cover the electrode surface. This can cause the signal current to decay over time, which is called electrode fouling or electrode passivation. This paper describes a model based on the potential drop across the fouling layer that is helpful for deeper understanding of th...
A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...
We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...
Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the...
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
the voltammetric performance of edge-plane pyrolytic graphite (epg) electrode via adsorptive stripping voltammetry was investigated for study of the electrochemical behavior of omeprazole (omz) in aqueous solution. the results revealed that the oxidation of omz is an irreversible ph-dependent process that proceeds with the transfer of one electron and one proton in an adsorption-controlled mech...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید