نتایج جستجو برای: driven cross ventilation

تعداد نتایج: 753999  

Journal: :E3S web of conferences 2023

Due to insufficient ventilation, public toilets have become incubators for cross-infection during the pandemic. WHO has proposed an approach improve indoor including ventilation in isolated spaces like toilets, by applying 10L/s/person criteria, and keeping fans running effective ventilation. However, less air inflow many causes We ever found colony forming units (CFUs) staying surrounding floo...

دهقانی اشکذری, محمد رضا, نایب زاده, شهناز, کریمی نیری, میترا,

Background: Internal marketing motivates the domestic customers by meeting their needs. Employee-driven work systems can improve the capabilities and motivations of the workforce to perform better in the organization. The purpose of this study was to investigate the effect of internal marketing and employee-driven work systems on job satisfaction with respect to job attractiveness. Methods: Th...

2006
Yi Jiang Qingyan Chen

Full-scale experimental and computational fluid dynamics (CFD) methods were used to investigate buoyancy-driven single-sided natural ventilation with large openings. Detailed airflow characteristics inside and outside of the room and the ventilation rate were measured. The experimental data were used to validate two CFD models: Reynolds averaged Navier-Stokes equation (RANS) modeling and large ...

2006
G. Carrilho da Graça

This paper presents a performance evaluation of two passive cooling strategies, daytime ventilation and night cooling, for a generic, six-story suburban apartment building in Beijing and Shanghai. The investigation uses a coupled, transient simulation approach to model heat transfer and airflow in the apartments. Wind driven ventilation is simulated using computational fluid dynamics (CFD). Occ...

Journal: :Journal of Wind Engineering and Industrial Aerodynamics 2018

Journal: :Respiratory care 2014
Andrey Pavlov Rostislav Muravyev Yaw Amoateng-Adjepong Constantine A Manthous

BACKGROUND Previous studies suggest that some medications, including proton pump inhibitors and β-agonist inhalers, are administered to hospitalized patients and sometimes continued without indications. Medication reconciliation has been offered as one mechanism to reduce the frequency of such medication errors and is now mandated by the Joint Commission (NPSG.03.06.01). We hypothesized that (1...

2005
P. F. Linden

Natural ventilation of buildings is the flow generated by temperature differences and by the wind. The governing feature of this flow is the exchange between an interior space and the external ambient. Although the wind may often appear to be the dominant driving mechanism, in many circumstances temperature variations play a controlling feature on the ventilation since the directional buoyancy ...

Journal: :Herald of Dagestan State Technical University. Technical Sciences 2017

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید