نتایج جستجو برای: dosimetry protocols

تعداد نتایج: 108295  

2017
Daniel Taussky Levon Igidbashian David Donath Dominic Béliveau-Nadeauv Renée X. Larouche Yanick Hervieux Guila Delouya

PURPOSE To analyze intraoperative (IO) dosimetry using transrectal ultrasound (TRUS), performed before and after prostate low-dose-rate brachytherapy (LDR-BT), and compare it to dosimetry performed 30 days following the LDR-BT implant (Day 30). MATERIAL AND METHODS A total of 236 patients underwent prostate LDR-BT using 125I that was performed with a three-dimensional TRUS-guided interactive ...

Journal: :Nucleation and Atmospheric Aerosols 2021

A new development of a linear accelerator machine has been installed in Indonesia for the first time. There is no dosimetric protocol specifically discussing measurement absorbed dose to water Halcyon linac. But, few global protocols determine linac which at same substance. This paper describes dosimetry parameter 6 MV flattening filter-free (FFF) photon beam produced from model Varian using IA...

2012
C. M. M. Paschoal M. L. Sobrinho D. do N. Souza J. Antônio Filho L. A. P. Santos

Computed tomography (CT) dosimetry normally uses an ionization chamber 100 mm long to estimate the computed tomography dose index (CTDI), however some reports have already indicated that small devices could replace the long ion chamber to improve quality assurance procedures in CT dosimetry. This paper presents a novel dosimetry system based in a commercial phototransistor evaluated for CT dosi...

رحیمی, علی , مهدوی, ربیع , مولانا, هادی , هاشمی , بیژن ,

Abstract Background and purpose: Estimating dosimetric parameters for small fields at non-reference conditions lead to significant errors if they are done based on the conventional protocols used for large fields and reference conditions. The aim of this study was to determine and compare small fields correction factors (KNR and KNCSF) based on a novel protocol by using different types of d...

Journal: :Medical Physics 2021

The American Association of Physicists in Medicine (AAPM) formed Task Group 178 (TG-178) to perform the following tasks: review in-phantom and in-air calibration protocols for gamma stereotactic radiosurgery (GSR), suggest a dose rate protocol that can be successfully utilized with all (GSR) devices, update quality assurance (QA) TG-42 (AAPM Report 54, 1995) static GSR devices. TG-178 report re...

Journal: :Regulatory Toxicology and Pharmacology 2021

Despite the growing numbers of studies on cigarettes and electronic nicotine delivery products (ENDs), no standard assessment stability in various matrix post exposure is currently available. The aim present study was to evaluate optimal condition store Cambridge Filter Pads (CFPs) before chemical analysis order guarantee titer nicotine.We further performed data normalization according differen...

2014
Antony L Palmer David Bradley Andrew Nisbet

The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple-channel dosimetry has recently been utilized in exte...

Journal: :Medical physics 2016
Joanna Cygler

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation T...

2002
Vadim CHUMAK

The paper is devoted to review of development and application of EPR dosimetry with teeth in Ukraine. It deals with specific features of the EPR dosimetry protocol, which was developed and is practically used in SCRM for retrospective dosimetry of clean-up workers (liquidators). Extensive methodological research was conducted in SCRM in order to develop an original version of EPR dosimetric pro...