نتایج جستجو برای: dose calibrator

تعداد نتایج: 311008  

Journal: :Clinical chemistry 2009
Angela M Caliendo Mona D Shahbazian Carl Schaper Jessica Ingersoll Deborah Abdul-Ali Jerry Boonyaratanakornkit Xiao-Li Pang Julie Fox Jutta Preiksaitis E Ralf Schönbrunner

BACKGROUND Viral load testing for cytomegalovirus (CMV) is an important diagnostic tool for the management of transplant recipients and immunocompromised individuals; however, inconsistency among laboratories in quantitative measurements of viral load limits interinstitutional comparisons. These inconsistencies stem from the lack of assays cleared by the US Food and Drug Administration, the abs...

Journal: :Respiratory care 2011
Jennifer A Bunn Jesse L Pittsley Scott V Baker Jw Yates

BACKGROUND Few have examined the accuracy of mechanical calibrators used to calibrate metabolic monitors. OBJECTIVE To evaluate the Vacu-Med 17053 motorized syringe calibrator for accuracy against the accepted standard method: the Douglas bag. METHODS We tested oxygen consumption values (V(O(2))) of 522-3,210 mL/min. We mixed room air and calibration gases in the pumping syringes of the Vac...

Journal: :Journal of clinical microbiology 2013
G Marshall Lyon Deborah Abdul-Ali Juergen Loeffler P Lewis White Brian Wickes Monica L Herrera Barbara D Alexander Lindsey R Baden Cornelius Clancy David Denning M Hong Nguyen Michele Sugrue L Joseph Wheat John R Wingard J Peter Donnelly Rosemary Barnes Thomas F Patterson Angela M Caliendo

Twelve laboratories evaluated candidate material for an Aspergillus DNA calibrator. The DNA material was quantified using limiting-dilution analysis; the mean concentration was determined to be 1.73 × 10(10) units/ml. The calibrator can be used to standardize aspergillosis diagnostic assays which detect and/or quantify nucleic acid.

Journal: :Clinical chemistry and laboratory medicine 2009
Vratislav Chromý Lenka Sváchová Lukás Novosád Jirí Jarkovský Pavel Sedlák Petr Horák Hana Dobrovolná Barbora Hlavácová

BACKGROUND Assay of total serum protein by the biuret method calibrated with albumin standards according to the reference method provides results with a positive bias approximately 3%-5% exceeding the total error of 3.4% allowable for total protein in serum analysis made by analysers using two-part reagents and short-term procedures. METHODS We used two types of two-part biuret reagents utili...

Journal: :The Astrophysical Journal Supplement Series 2002

Journal: :The Journal of Automatic Chemistry 1985
Maria Luisa Gozzo Giuliano Barbaresi Francesco Dalla Torre Gianpaolo Littarru Cecilia Zuppi

1998
J. C. Mather D. J. Fixsen R. A. Shafer C. Mosier D. T. Wilkinson

The photometric errors of the external calibrator for the FIRAS instrument on the COBE are smaller than the measurement errors on the cosmic microwave background (CMBR) spectrum (typically 0.02 MJy/sr, 1 σ), and smaller than 0.01% of the peak brightness of the CMBR. The calibrator is a re-entrant cone, shaped like a trumpet mute, made of Eccosorb iron-loaded epoxy. It fills the entire beam of t...

Journal: :Journal of nuclear medicine technology 2011
Arnold F Jacobson Robert Centofanti Olakiitan I Babalola Brian Dean

UNLABELLED The accuracy with which (123)I activity is measured by a dose calibrator depends on the composition and geometry of the source. The present study assessed the variability of current commercial dose calibrators in assaying liquid (123)I samples. METHODS A calibration procedure for (123)I measurement was performed on 177 dose calibrators (11 manufacturers) at 138 sites in North Ameri...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید