نتایج جستجو برای: dimensional 3

تعداد نتایج: 2143956  

2008
András Recski Dávid Szeszlér

Consider a single planar grid, or two parallel planar grids of size w × n. The vertices of the grids are called terminals and pairwise disjoint sets of terminals are called nets. We aim at routing all nets in a cubic grid (above the single grid, or between the two grids holding the terminals) in a vertex-disjoint way. However, to ensure solvability, it is allowed to extend the length and the wi...

2007
Attila Reiss Dávid Szeszlér

Consider two parallel planar grids of size w×n. The vertices of these grids are called terminals and pairwise disjoint subsets of terminals are called nets. We aim at routing all nets in a cubic grid between the two layers holding the terminals. However, to ensure solvability, it is allowed to introduce an empty row/column between every two consecutive rows/columns containing the terminals (in ...

Journal: :the archives of bone and joint surgery 0
tessa drijkoningen orthopaedic hand and upper extremity service, massachusetts general hospital, boston, usa robert knotter emergency department, reinier de graaf gasthuis, delft, the netherlands frank j. beeres surgery department, medisch centrum haaglanden, den haag, the netherlands emile g. coerkamp radiology department, medisch centrum haaglanden, den haag, the netherlands anton h.j. koning department of bioinformatics, erasmus mc university medical center, rotterdam, netherlands steven j. rhemrev surgery department, medisch centrum haaglanden, den haag, the netherlands

background: the i-space is a radiological imaging system in which computed tomography (ct)-scans can be evaluated as a three dimensional hologram. the aim of this study is to analyze the value of virtual reality (i-space) in diagnosing acute occult scaphoid fractures.   methods: a convenient cohort of 24 patients with a ct-scan from prior studies, without a scaphoid fracture on radiograph, yet ...

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

Journal: :Proceedings of the Japan Academy, Series A, Mathematical Sciences 1982

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید