نتایج جستجو برای: diagnostic reference level entrance surface dose digital x ray examination entrance surface air kerma
تعداد نتایج: 3457604 فیلتر نتایج به سال:
Introduction:Intravenous urography (IVU) test includes high number of images and extended imaging size. These make IVU as a diagnostic method with high absorbed doses by sensitive organs such as intestine and gonads in pelvic-abdominal area. In this study absorbed doses of pelvic-abdomen sensitive organs such as Adrenal, Bladder, Colon and Gonads in IVU test. <stron...
Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...
OBJECTIVE: To develop a double-faced plane-parallel ionization chamber for measurement of air kerma and air kerma rate in X-radiation fields utilized in conventional radiography and mammography. MATERIALS AND METHODS: The chamber has entrance windows made of aluminized polyester film, inner and guard electrodes of aluminum at one side (face A) and graphite at the other side (face G). The presen...
The purpose of this study was to assess the level of patient radiation dose received in general fluoroscopy examinations, compare the findings with the international diagnostic reference levels (IDRLs), and establish the initial institutional (local) LDRLs. A comprehensive survey was conducted for general fluoroscopy examinations using the medical records of a Radiology Department of a leading ...
Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs) in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State,...
BACKGROUND X-ray use in the catheterization laboratory is guided by the principle of as low as reasonably achievable. In accordance with this principle, we reduced the default fluoroscopic frame rate from 10 to 7.5 frames/s and increased the emphasis on the use of low-dose acquisition starting January 1, 2013. We aimed to study the impact of these measures on the total air kerma during diagnost...
Acceptance testing and commission are essential elements of the quality assurance program for imaging equipment. We present results a performance evaluation Flat Panel-Based Cardiovascular Fluoroscopy X-ray Systems as part acceptance commissioning. Measurements were obtained using calibrated dose rate meter, patient equivalent phantoms, Leeds image test tools. The compared with manufacturer Eur...
BACKGROUND AND PURPOSE Radiation exposure from neurointerventional procedures can be substantial, with risk of radiation injuries. We present the results of a follow-up program applied to potential skin injuries in interventional neuroradiology based on North American and European guidelines. MATERIALS AND METHODS The following guidelines approved in 2009 by SIR and CIRSE have been used over ...
PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید