نتایج جستجو برای: detector system

تعداد نتایج: 2274045  

Journal: :IEEE Transactions on Nuclear Science 2004

Journal: :Journal of Physics: Conference Series 2011

Bonner spheres system is one of the ways of measuring neutron energy distribution which is often applied in spectrometry and neutron dosimetry. This system includes a thermal neutron detector, being located in the center of several polyethylene spheres, and it is still workable due to the isotropic response of the system which in turn is derived from the spherical symmetry of moderators and the...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1390

abstract ion selective electrodes (ises) are electrochemical sensors that respond selectivity to the activity of ionic species. an ion-selective electrode is an electrochemical device that uses a thin selective membrane or film as the recognition element, and is an electrochemical half-cell equivalent to other half-cells of the zeroth (inert metal in a redox electrolyte). in common methods o...

جاوید دبیری, , جواد رحیقی, , حسین قدس, , مهرداد عزیزی شمامی, ,

  Interaction of fast neutrons with oxygen atoms of cooling water in reactor core leads to the production of 16N isotope which emits 6.13 MeV gamma ray. A system is developed to measure the 16N gamma ray activity using a5.08cm ×5.08cm NaI(Tl) detector. A suitable electronic system is used to count 16N gamma rays in different reactor powers in order to calibrate the 16N system in terms of reacto...

2007
Piotr Zielinski

Eventual failure detectors, such as Ω or ♦P, can make arbitrarily many mistakes before they start providing correct information. This paper shows that any detector implementable in a purely asynchronous system can be implemented as a function of only the order of most-recently heard-from processes. The finiteness of this representation means that eventual failure detectors can be enumerated and...

2004
Laura Cottatellucci Ralf R. Müller Mérouane Debbah

We consider a linear multistage detector with universal (large system) weighting for large asynchronous code-division multiple-access (CDMA). A convenient choice of the basis of the projection subspace allows a joint projection of all users’ signals and avoids truncation effects due to finite time windowing. Thanks to the joint projection the complexity per bit of the proposed detector scales l...

Journal: :iranian journal of radiation research 0
a.t. al-kinani supreme council for environment and natural reserves, doha, qatar, a.s. al-saidi s. al-anni

abstract   background : the application of du emanation for first time contaminated certain areas in the south west region of iraq after the second gulf war (1991). these contaminated areas were discovered in 1994. radioactive contamination was detected using the nuclear enterprise pcm5/1 in soil samples collected from two regions near by grazing lands. this study was done for assessment of du ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید