Kamal A M Solaiman Sameh M Fouda Ashraf Bor'i Haitham Y Al-Nashar

Purpose. To evaluate the safety, efficacy, and predictability of photorefractive keratectomy (PRK) on the corneal flap for correction of residual myopia following myopic laser in situ keratomileusis (LASIK). Patients and Methods. A retrospective study on eyes retreated by PRK on the corneal flap for residual myopia after LASIK. All eyes had no enough stroma after LASIK sufficient for LASIK enha...

Journal: :journal of current ophthalmology 0
محمد ریاضی اصفهانی mohammad riazi esfahani ابراهیم جعفرزاده پور ebrahim jafarzadehpur حسن هاشمی hassan hashemi الینا غفاری elina ghaffari

purpose : to evaluate corneal visco-elasticity and intraocular pressure (iop) changes measured by an ocular response analyzer (ora) after scleral buckling methods : fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. corneal hysteresis (ch), corneal resistance factor (crf), corneal-compensated iop (iopcc) and goldmann-correlated iop (iopg) were m...

Journal: :بینا 0
سپهر فیضی s feizi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم محمد پاکروان m pakravan ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم پرویز ملکی فر p malekifar ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم محمدعلی جوادی ma javadi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم

purpose: to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and to evaluate the influence of anatomical and biomechanical properties of the grafts on iop measurements. methods: this cross-sectional study was conducted on 45 kerat...

2016
Sadık Görkem Çevik Sertaç Argun Kıvanç Berna Akova-Budak Mediha Tok-Çevik

Purpose. To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group. Methods. This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects. The anterior segment parameters and geometric corneal parameters such as corneal vo...

2016
Hazem Helmy Mahmoud Leila Ahmed Atef Zaki

PURPOSE We aimed to assess corneal biomechanics using the ocular response analyzer in patients with normal-tension glaucoma (NTG), and to evaluate the relationship between corneal biomechanics and visual field loss. METHODS This was a prospective observational case series including patients with bilateral asymmetric NTG. For all patients, corneal hysteresis (CH), corneal resistance factor (CR...

2015
Wenjing Wu Yan Wang

Background. To investigate the correlation between corneal biomechanics and the surgically induced corneal high-order aberrations (HOAs) after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK). Methods. A total of 150 right myopic eyes that underwent SMILE or FS-LASIK surgery were included in this retrospective study, 75 eyes in each group. The ...

2015
Joanna Wasielica-Poslednik Christina Butsch Christina Lampe Heike Elflein Julia Lamparter Veronika Weyer Susanne Pitz Sanjoy Bhattacharya

AIMS To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA). METHODS MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in...

Journal: :Investigative ophthalmology & visual science 2008
Javier Moreno-Montañés Miguel J Maldonado Noelia García Loreto Mendiluce Pio J García-Gómez María Seguí-Gómez

PURPOSE To assess the reproducibility of the ocular response analyzer (ORA) in nonoperated eyes and the impact of corneal biomechanical properties on intraocular pressure (IOP) measurements in normal and glaucomatous eyes. METHODS In the reliability study, two independent examiners obtained repeated ORA measurements in 30 eyes. In the clinical study, the examiners analyzed ORA and IOP-Goldman...

Journal: :Investigative ophthalmology & visual science 2011
William Lau David Pye

PURPOSE To examine the interrelationships among the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY), Goldmann applanation tonometer (GAT), and corneal geometry measurements in a young, healthy sample. METHODS Central corneal radius, ORA, GAT, and central corneal thickness (CCT) measurements were taken in 99 subjects (age, 21 ± 2 years) who were free of ocular and ...

2016
XiaoBo Zheng FangJun Bao Brendan Geraghty JinHai Huang AYong Yu QinMei Wang

BACKGROUD To evaluate the symmetry of corneal biomechanical metrics, measured using an ocular response analyzer (ORA) and self-built corneal inflation test platform, in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure (IOPp). METHODS Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole ocular globe inflation. IOP was increa...