نتایج جستجو برای: cobalt determination
تعداد نتایج: 280306 فیلتر نتایج به سال:
Reaction of cis-diazidobis(ethylenediamine)cobalt(III)nitrate with ammonium thiocyanate in a 1 : 2 molar ratio in aqueous medium gave the title cobalt(III) compound, cis-[Co(en)2(N3)2]SCN, as reddish brown crystals in almost quantitative yield. The complex salt was characterized by elemental analysis, IR, electronic, H and C NMR spectroscopic studies. An X-ray structure determination revealed a...
Flow injection-solid phase spectrometry (FI-SPS) has been applied to the determination of cobalt(II) in water samples. The complex formed between cobalt and 5-Br-PADAB was on-line protonated and concentrated on an AG 50W-X2 cation-exchanger in a flow-through cell. The increase in absorbance caused by the accumulation of the complex in the resin was continuously measured. The interference by cop...
A new approach for developing a cloud-point extraction-flame atomic absorption spectrometric method has been described and used for the determination of cobalt. In this approach, water was removed from the final diluted surfactant rich phase obtained in cloud-point extraction procedure. The results indicated that removing water from this phase increased the enhancement factor by 4-fold. 1-(2-Py...
Carbon paste electrode modified with cobalt impregnated zeolite was prepared by mixing of cobalt_zeolite (Co_Z) and graphite powder with different percent. The electrochemical oxidation of cefixime at such electrodes was investigated using the cyclic voltammetric and amperometric techniques. It is not electrochemically active towards cefixime oxidation in 0.1 M phosphate buffer solution (pH=7) ...
BACKGROUND In vivo assessment of inflammatory responses in the synovia of patients with MoM hip replacements would be useful in the determination of the prognosis of the hip replacement. Aims of the study was to investigate the correlation between cobalt and chrome levels in joint fluid with histopathological findings and the predictive ability of metal ion levels for these findings. METHODS ...
in this work, a new spectrophotometric method for the determination of trace amount of cobalt (іі) ionwas investigated and the stability constant of the related complex was evaluated 2.174 × 104. in the cobalt(іі)-piroxicam complex, the maximum absorbance wavelength is 570 nm and the linearity of calibrationcurve was investigated (5-10 ppm). the relative standard deviation for seven replicate e...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید