Lavanya Govindaraju Ganesh Jeevanandan E. M. G. Subramanian

OBJECTIVE In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files sy...

Malekipour, Mohammad Reza, Sobhi, Fatemeh, Zare Jahromi, Maryam,

Extra oral comparison of smear layer removal from root canals when using phosphoric acid and RCprep–NaOCL: A SEM study Dr. M. Zare Jahromi * - Dr. MR. Malekipour ** - Dr. F. Sobhi *** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Khorasgan Islamic Azad University. **Assistant Professor of Operative Dentistry Dept., Faculty of Dentistry, Khorasgan Islamic Azad University. ***D...

Journal: :iranian endodontic journal 0
amin salem milani assistant professor of endodontic department of tabriz dental school mohammad froughreyhani assistant professor, department of endodontics, faculty of dentistry, tabriz university of medical sciences, tabriz, iran. saeed rahimi professor of endodontics, department of endodontics, faculty of dentistry, tabriz university of medical sciences, tabriz, iran. mohammad asghari jafarabadi assistant professor of biostatistics, national public health management center (npmc) and department of statistics and epidemiology, tabriz university of medical sciences, tabriz, iran. sara paksefat postgraduate student, department of endodontics, faculty of dentistry, tabriz university of medical sciences, tabriz, iran.

introduction: root fracture is not an instant phenomenon but a result of gradual development of tiny craze lines in tooth structure. recent studies have shown that canal instrumentation has the potential to cause dentinal cracks. the purpose of this study was to evaluate and compare the formation of dentinal cracks caused by protaper rotary system to hand instrumentation. materials and methods:...

2016
Himanshu Dixit Manoj Nair Nitin Shah Varsha Pandit

ROOT CANAL INSTRUMENTATION

Journal: :Acta stomatologica Croatica 2015
Jorge Rubio José Ignacio Zarzosa Antonio Pallarés

PURPOSE This study compared the cutting area, instrumentation time, root canal anatomy preservation and non-instrumented areas obtained by F360(®), Mtwo(®), RaCe(®) and Hyflex(®) files with ISO size 35. MATERIAL AND METHODS 120 teeth with a single straight root and root canal were divided into 4 groups. Working length was calculated by using X-rays. The teeth were sectioned with a handpiece a...

Journal: :International endodontic journal 2015
S Bürklein D Mathey E Schäfer

AIM To compare the shaping ability of four different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 80 root canals with curvatures ranging between 25° and 39° were divided into four groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radi...

2017
Randy W Garland

Due to limitations in standard endodontic therapy there have been great endeavors to effectively clean, shape and disinfect the root canal system while preserving the natural anatomy of the tooth [1]. Maintaining the natural canal anatomy and preservation of tooth structure has been correlated to higher clinical success rates [2-5]. A major issue in tooth preservation is the need to maximize cl...

Journal: :Brazilian dental journal 2011
Mateus Silveira Martins Hartmann Vânia Regina Camargo Fontanella José Roberto Vanni Volmir João Fornari Fernando Branco Barletta

This study used computed tomography (CT) to compare apical canal transportation in mesiobuccal canals of maxillary molars prepared with different techniques. Sixty teeth were assigned to 3 groups (n=20), according to the technique used for root canal instrumentation: hand instrumentation with K-Flexofiles, K-Flexofiles activated by an oscillatory system and ProTaper NiTi rotary system. Pre and ...

ژورنال: دانشور پزشکی 2008
لباف, حسین , نادرالوجود, محمدحسین , هنردار, کیامرث ,

  Background: Stainless steel instruments have long used as conventional instruments applied in root canal therapy procedures. Being difficult the canal preparation by these instruments, a new generation of nickel-titanium instruments have introduced. The aim of this study was to compare the manual Ni-Ti instruments with the Flex Master® Ni-Ti rotary system in canal preparation.   Materials & M...

Javidi, Maryam, Vatanpour, Mehdi, Zarei, Mina,

Comparison of canal transportation after preparation by 3 different rotary systems Dr. Javidi, M.* - Dr. Zarei, M.* - Dr. Vatanpour, M.** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Tehran Azad University. Abstract Background & Aim: Cleaning and shaping has been recogni...