نتایج جستجو برای: calibration plot
تعداد نتایج: 86483 فیلتر نتایج به سال:
As the oven temperature is raised at a reproducible rate, analytes are eluted and the areas under the chromatogram are recorded. Boiling points are assigned to the time axis from a calibration curve, known as the boiling-point distribution curve, based on a known mixture of normal paraffin hydrocarbons over a fixed range. These paraffin hydrocarbons serve as markers, which identify the time tha...
A study of a simple and sensitive method for the determination of berberine, luguine and sanguinarine in mixtures by normal and synchronous derivative spectrofluorimetry is described. The influence of solvents and other experimental variables is discussed. A three-dimensional plot of both emission-excitation and synchronous spectra obtained by a new software program provides additional informat...
For two watersheds in the northern Midwest United States, we show that landscape depressions have a significant impact on watershed hydrology and sediment yields and that the Soil and Water Assessment Tool (SWAT) has appropriate features to simulate these depressions. In our SWAT models of the Willow River in Wisconsin and the Sunrise River in Minnesota, we used Pond and Wetland features to cap...
This paper describes a simple, sensitive and environmentally benign method for the direct determination of aniline and its derivatives in environmental water samples by capillary zone electrophoresis (CZE) with field-enhanced sample injection. The parameters that influenced the enhancement and separation efficiencies were investigated. Surprisingly, under the optimized conditions, two linear ra...
A fence post design, when viewed on a plot of index of refraction versus film thickness, has thin (usually of equal thickness) high-index posts that stand above a broad low-index ground. Monitoring fence post and related posthole designs offers error compensation and error reduction. There tend to be two or more extrema within the optical monitoring trace of each layer between the fence posts t...
G-100 is used for higher molecular mass proteins. The solutions of proteins are prepared in guanidine hydrochloride (10 mg mL ), and cytochromec (10 mg mL ) is used as an internal standard. Descending chromatography is carried out at room temperature under an inclination angle of 253 to the horizontal. After 3 h of development the quotient Rs protein/Rs cytochrome c is calculated for each prote...
May 16, 2016 Type Package Title Calibration Plot for Proteomics Version 0.3.5 Date 2016-05-11 Author Quentin Giai Gianetto, Florence Combes, Claire Ramus, Christophe Bruley, Yohann Couté, Thomas Burger Maintainer Quentin Giai Gianetto Description Functions to check whether a vector of p-values respects the assumptions of FDR (false discovery rate) control procedures and to ...
Single-walled carbon nanohorn (SWCNH) was developed as new adsorbent for solid-phase extraction using 4-nitrophenol as representative. The unique exoteric structures and high surface area of SWCNH allow extracting a large amount of 4-nitrophenol over a short time. Highly sensitive determination of 4-nitrophenol was achieved by linear sweep voltammetry after only 120s extraction. The calibration...
A new simple rapid and sensitive spectrophotometric method has been developed for the determination of ketoprofen in pharmaceutical preparations. The method is based on the reaction of ketoprofen with an analytical reagent--Astra Phloxin FF--at pH 8.0-10.8 and followed by the extraction of formed ion associate in toluene with spectrophotometric detection (it has an absorption maximum at 563 nm,...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید