نتایج جستجو برای: bod biochemical oxygen demand

تعداد نتایج: 478930  

2017
Yingrong Wen Gerrit Schoups Nick van de Giesen

Organic pollution of rivers by wastewater discharge from human activities negatively impacts people and ecosystems. Without treatment, pollution control relies on a combination of natural degradation and dilution by natural runoff to reduce downstream effects. We quantify here for the first time the global sanitation crisis through its impact on organic river pollution from the threats of (1) i...

Journal: :Water research 2010
Mark A Jordan David T Welsh Peter R Teasdale Kylie Catterall Richard John

Activated sludge was successfully incorporated as the biocatalyst in the fast, ferricyanide-mediated biochemical oxygen demand (FM-BOD) bioassay. Sludge preparation procedures were optimized for three potential biocatalysts; aeration basin mixed liquor, aerobic digester sludge and return activated sludge. Following a 24h starving period, the return activated sludge and mixed liquor sludges repo...

Journal: :IOP conference series 2021

Agricultural runoff is non-point source pollution that unpredictable and difficult to control. Best Management Practices (BMPs) Low Impact Development (LID) has been utilized as a method manage agricultural runoff. Treatment train systems are LID-BMPs arranged in series aims treat This study focuses on the use of treatment reduce concentration BOD A system was set up with three varying configur...

Journal: :International journal of environmental research and public health 2004
Susheel K Mittal Siloni Goel Ajay Sharma

The toxic effect of metal ions like chromium (Cr3+), cobalt (Co2+), nickel (Ni2+), copper (Cu2+), cadmium (Cd2+) and lead (Pb2+) on biochemical oxygen demand (BOD) of synthetic wastewater samples has been studied at different temperatures i.e., 15 degrees C, 20 degrees C, 25 degrees C and 30 degrees C. Experiments were conducted for BOD exertion in presence (10 ppm of each metal ion) and in the...

Journal: :Journal of water and health 2011
Tasneem Abbasi S A Abbasi

Water quality indices (WQIs), which translate numerical values of several water quality characteristics of a sample into a single value, play a very important role in the monitoring, comparison and control of water quality. The WQIs of modern and post-modern times have been almost exclusively based on physical and chemical characteristics, and have seldom included 'biological' characteristics o...

Journal: :تحقیقات نظام سلامت 0
شاهرخ رضایی دانشجوی کارشناسی ارشد، کمیته تحقیقات دانشجویی، مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران محمد مهدی امین دانشیار، مرکز تحقیقات محیط زیست، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران احمد موحدیان عطار استاد، گروه بیوشیمی، دانشکده داروسازی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران حمیده ابراهیمی کارشناس آزمایشگاه، تصفیه خانه فاضلاب شهرک صنعتی مورچه خورت اصفهان، شهرک صنعتی اصفهان، اصفهان، ایران اکبر نازک کار کارشناس، گروه بیوشیمی، دانشکده داروسازی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران

background: soluble microbial products (smps) have an effective role on fouling of membrane in bioreactors (mbrs). the aim of this study was to survey the role of smps on mbrs used in treating municipal wastewater. materials: lowry and phenol sulfuric acid methods were used to measure carbohydrates concentrations and protein content, respectively. biochemical oxygen demand (bod), chemical oxyge...

2017
Gab-Joo Chee

Population growth and industrialization have caused serious environmental pollution. Environmental pollution has become global issues beyond a region or a country, and is the introduction of contaminants, which are synthetic chemicals, pesticides, and heavy metals etc, into environmental system. Biopersistent organic chemicals of them particularly cause instability, disorder, harm or discomfort...

2017
Stanley Irobekhian Reuben Okoduwa Bernard Igiri Chinyere Blessing Udeh Chidi Edenta Balli Gauje

The quest for an effective alternative means for effluent treatment is a major concern of the modern-day scientist. Fungi have been attracting a growing interest for the biological treatment of industrial wastewater. In this study, Saccharomycescerevisiae and Torulasporadelbrueckii were isolated from spoiled watermelon and inoculated into different concentrations of effluent. The inoculants wer...

Journal: :Bioresource technology 2009
Cristina S C Calheiros António O S S Rangel Paula M L Castro

Industrial wastewater treatment comprises several processes to fulfill the discharge permits or to enable the reuse of wastewater. For tannery wastewater, constructed wetlands (CWs) may be an interesting treatment option. Two-stage series of horizontal subsurface flow CWs with Phragmites australis (UP series) and Typha latifolia (UT series) provided high removal of organics from tannery wastewa...

2015
Min-Chi Hsieh Chiu-Yu Cheng Man-Hai Liu Ying-Chien Chung

The conventional Biochemical Oxygen Demand (BOD) method takes five days to analyze samples. A microbial fuel cell (MFC) may be an alternate tool for rapid BOD determination in water. However, a MFC biosensor for continuous BOD measurements of water samples is still unavailable. In this study, a MFC biosensor inoculated with known mixed cultures was used to determine the BOD concentration. Effec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید