نتایج جستجو برای: auxiliary collimator

تعداد نتایج: 24268  

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 1983
A Brahme J Eenmaa S Lindbäck A Montelius P Wootton

The dose distributional properties of a p(50) Be neutron beam using a continuously variable multi-leaf collimator are presented and compared with a 6 MV photon beam. The differences in physical dose delivery between these two radiation modalities are generally insignificant for radiation therapy, and stringent comparisons of neutron and photon treatments should therefore be possible. The flexib...

2010
V.W.Y Choi E.H.W. Yum K. N. Yu

In the present paper, we propose a method to fabricate a ‘‘micro-collimator’’ with a thickness of 15mm. A commercially available PADC film with a thickness of 100mm was first chemically etched with NaOH/ethanol solution to obtain a thin PADC film. This thin PADC film was then irradiated by 5MeV a particles through a ‘‘macro-collimator’’ with a thickness of 5mm and a hole diameter of 1mm. This P...

Journal: :Physics in medicine and biology 1998
G L Zeng G T Gullberg

In single photon emission computed tomography (SPECT), a varying-focal-length cone-beam collimator can be used to reduce the truncation problem and to maintain sensitivity when imaging the organ of interest. The collimator is constructed so that the collimator holes focus to a circular symmetric, spatially varying, focal point function. The focal length increases radially from the shortest foca...

2001
C.-K. Ng T. O. Raubenheimer P. Tenenbaum

The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic...

Journal: :Medical physics 1998
T LoSasso C S Chui C C Ling

The use of a multileaf collimator in the dynamic mode to perform intensity modulated radiotherapy became a reality at our institution in 1995. Unlike treatment with static fields using a multileaf collimator, there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. We have performed a series of calculations and measurements to quantify head scatt...

2011
S. Xu V. Nagarajan R. Sanishvili

In October 2009, a quad, mini-beam collimator was implemented at GM/CA CAT that allowed users to select between a 5, 10, or 20 micron mini-beam or a 300 micron scatter guard for macromolecular crystallography [1]. Initial alignment of each pinhole to the optical axis of each path through the mini-beam collimator is performed under an optical microscope using an alignment jig. Next, the pre-alig...

Journal: :Kaku igaku. The Japanese journal of nuclear medicine 2001
S Itoh N Hiramatsu A Iwata K Yoshiya S Imai

PURPOSE AND METHODS The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emission computed tomography (SPECT), the procedure is complicated because we have to change the collimator. In phantom and clinical s...

2011
Mattijs Elschot Johannes Franciscus Wilhelmus Nijsen Alida Johanna Dam Hugo Wilhelmus Antonius Maria de Jong

BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...

2017
Shinro Matsuo Kenichi Nakajima Koichi Okuda Masaya Kawano Takehiro Ishikawa Tetsuo Hosoya Seigo Kinuya

Background. Although heart-to-mediastinum (H/M) ratio in a planner image has been used for practical quantification for I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of H/M can be standardized to the various types of camera-collimator combinations. Methods and Results. Standard phantoms consisting of the heart, ...

جوهری دها, فریبا, افتخاری, محمد, رجبی, حسین, طالشی آهنگری, هادی,

Background and purpose: Imaging which is used in nuclear medicine is done using emit gamma rays whereas therapy in nuclear medicine is performed by applying radionuclide’s which emit beta radiation. Using Bremsstrahlung is a new field which is recently introduced in imaging. In the Bremsstrahlung imaging, collimator design should not be based on energy peak and whole energy spectrum should be c...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید