نتایج جستجو برای: attenuation correction

تعداد نتایج: 212408  

Journal: :iranian journal of nuclear medicine 2011
faraz kalantari hossein rajabi mohsen saghari alireza emami ardekani

introduction: monte carlo (mc) is the most common method for simulating virtual spect projections. it is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of mc is its long run time. we introduced a model based method considering the effect of body attenuation and i...

Journal: :Journal of nuclear medicine technology 2005
Masuo Hayashi Jun Deguchi Keita Utsunomiya Makoto Yamada Tsuyoshi Komori Masayasu Takeuchi Kensei Kanna Isamu Narabayashi

OBJECTIVE The radioactivity count distribution in the brain must be determined accurately to accurately measure cerebral blood flow (CBF). Scatter and attenuation are factors that compromise the accuracy of determining radioactivity counts in the brain. METHODS We compared regional CBF in patients by an autoradiographic method using N-isopropyl-p-[123I] iodoamphetamine when, first, attenuatio...

2008
Joonki Noh Jeffrey A. Fessler Paul E. Kinahan

Dual-energy (DE) X-ray computed tomography (CT) has been proposed as an useful tool in various applications. One promising application is DECT with low radiation doses used for attenuation correction in positron emission tomography (PET). In low-dose DECT, conventional methods for sinogram decomposition have been based on logarithmic transformations and ignored noise properties, leading to very...

Journal: :journal of biomedical physics and engineering 0
h chaibi lab. litio university of oran 1 - algeria r nourine

background: one of the challenges of pet/mri combined systems is to derive an attenuation map to correct the pet image. for that, the pseudo-ct image could be used to correct the attenuation. until now, most existing scientific researches construct this pseudo-ct image using the registration techniques. however, these techniques suffer from the local minima of the non-rigid deformation energy f...

1997
Jack L. Parker

The nondestructive assay (NDA) of nuclear material must deal with large sample sizes and high self-absorption. Typical containers range from 2-L bottles to 220-L drums, and even a small sample with a high concentration of nuclear material has significant self-attenuation. Although gamma-ray self-attenuation may frequently be ignored in the filter papers or small vials encountered in radiochemic...

Journal: :Physics in medicine and biology 2015
Mootaz Eldib Jason Bini Philip M Robson Claudia Calcagno David D Faul Charalampos Tsoumpas Zahi A Fayad

The purpose of the study was to evaluate the effect of attenuation of MR coils on quantitative carotid PET/MR exams. Additionally, an automated attenuation correction method for flexible carotid MR coils was developed and evaluated. The attenuation of the carotid coil was measured by imaging a uniform water phantom injected with 37 MBq of 18F-FDG in a combined PET/MR scanner for 24 min with and...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
Adam M Alessio Steve Kohlmyer Kelley Branch Grace Chen James Caldwell Paul Kinahan

UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...

2002
Robert C. Hendel

Despite advancements in technologies, non-uniform soft tissue attenuation still affects the diagnostic accuracy of single photon emission computed tomography (SPECT) myocardial perfusion imaging. A variety of indirect measures have been used to reduce the impact of attenuation, most notably electrocardiography-gated SPECT imaging. However, all available techniques have limitations, making inter...

Journal: :NeuroImage 2005
Marie-Louise Montandon Habib Zaidi

Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Positron Emission Tomography (PET) images. This study investigates the implementation and applicability of transmission atlas-guided attenuation correction in cerebral 3D PET imaging, thus eliminating the need for acquisit...

Journal: :Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2002
Robert C Hendel James R Corbett S James Cullom E Gordon DePuey Ernest V Garcia Timothy M Bateman

Despite advancements in technologies, non-uniform soft tissue attenuation still affects the diagnostic accuracy of single photon emission computed tomography (SPECT) myocardial perfusion imaging. A variety of indirect measures have been used to reduce the impact of attenuation, most notably electrocardiography-gated SPECT imaging. However, all available techniques have limitations, making inter...