نتایج جستجو برای: aspheric intraocular lens

تعداد نتایج: 64758  

Journal: :Journal of cataract and refractive surgery 2011
Damien Gatinel Christophe Pagnoulle Yvette Houbrechts Laure Gobin

PURPOSE To theoretically and experimentally assess a new aspheric diffractive trifocal intraocular lens (IOL). SETTING Centre Spatial de Liège, Liège, Belgium. DESIGN Evaluation of diagnostic test or technology. METHODS The theoretical profile of the IOL was designed using software simulation and validated by optical calculation software tools that enabled complete theoretical characteriz...

2012
Reiner Friedrich

The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL) Tecnis ZMB00 (Abbott Medical Optics) are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years) underwent phacoemulsification surgery with implantation of this aspheric mu...

Journal: :Journal of refractive surgery 2017
Tamer Tandogan Hyeck Soo Son Chul Young Choi Michael C Knorz Gerd U Auffarth Ramin Khoramnia

PURPOSE To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing. METHODS Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Ze...

Journal: :GEORGIAN SCIENTISTS 2022

The article describes the method of calculating optical parameters second, aspherical lens based on known first spherical in a two-lens collimating system. allows to write parametric equation aspheric profile an explicit form.

2007
A. Denoyer J. Halfon S. Majzoub P.-J. Pisella

Purpose: To assess the quality of vision in pseudophakic patients with aspheric intraocular lens (IOL) without spherical aberration compared to patients with spherical IOL. Methods: Twenty-four patients (48 eyes) undergoing cataract surgery were randomly divided into two groups: 12 patients received an aspheric IOL in both eyes and 12 received spherical IOLs. The integrity of ocular functions w...

Journal: :Vision Research 2001
M. Dubbelman G. L. Van der Heijde

Scheimpflug slit images of the crystalline lens are distorted due to the refracting properties of the cornea and because they are obliquely viewed. We measured the aspheric curvature of the lens of 102 subjects ranging in age between 16 and 65 years and applied correction for these distortions. The procedure was validated by measuring an artificial eye and pseudophakic patients with intraocular...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید