نتایج جستجو برای: 99mtc tetrofosmin

تعداد نتایج: 4945  

Journal: :Circulation 1998
M G Gunning C Anagnostopoulos C J Knight J Pepper E D Burman G Davies K M Fox D J Pennell P J Ell S R Underwood

BACKGROUND Both radionuclide perfusion tracers and contractile response to dobutamine have been used to identify hibernating myocardium. The aim was to compare 201Tl (thallium) single photon emission CT (SPECT), 99mTc-tetrofosmin (tetrofosmin) SPECT, and dobutamine cine MRI for identifying regions of reversible myocardial dysfunction. METHODS AND RESULTS Thirty patients with 3-vessel coronary...

Journal: :Annals of nuclear medicine 2004
Tomohiro Kaneta Hideyuki Kurihara Takashi Hakamatsuka Hiroshi Ito Shin Maruoka Hiroshi Fukuda Shoki Takahashi Shogo Yamada

OBJECTIVE 123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99mTc-tetrofosmin (TET) are widely used for evaluation of myocardial fatty acid metabolism and perfusion, respectively. ECG-gated TET SPECT is also used for evaluation of myocardial wall motion. These tests are often performed on the same day to minimize both the time required and inconvenience to patients and medical...

Journal: :Journal of nuclear medicine technology 2011
Fatma J Al-Saeedi Milad Bitar Smitha Pariyani

UNLABELLED This study was done to examine the effect of asiaticoside on MCF-7 cell uptake of (99m)Tc-tetrofosmin ((99m)Tc-Tfos) and (99m)Tc-sestamibi ((99m)Tc-MIBI). METHODS The 3-(4,5-dimethylthiozol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was used to evaluate the effect of a 50% inhibitory concentration of asiaticoside on MCF-7 cell proliferation. MCF-7 cells were treated with 10,...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2016
Rene Nkoulou Tobias A Fuchs Aju P Pazhenkottil Silke M Kuest Jelena R Ghadri Julia Stehli Michael Fiechter Bernhard A Herzog Oliver Gaemperli Ronny R Buechel Philipp A Kaufmann

Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. METHODS A...

Journal: :BMC Medical Imaging 2006
Paschalis Tossios Jochen Müller-Ehmsen Matthias Schmidt Christof Scheid Nermin Ünal Detlef Moka Robert H. G. Schwinger Uwe Mehlhorn

BACKGROUND We tested the hypothesis, that intramyocardial injection of mononuclear bone marrow cells combined with coronary artery bypass grafting (CABG) surgery improves tissue viability or function in infarct regions with non-viable myocardium as assessed by nuclear imaging techniques. METHODS Thus far, 7 patients (60 +/- 10 [SD] years) undergoing elective CABG surgery after a myocardial in...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2008
Kai Kendziorra Henryk Barthel Sandra Erbs Frank Emmrich Rainer Hambrecht Gerhard Schuler Osama Sabri Regine Kluge

UNLABELLED Even after recanalization of a chronic total coronary occlusion, functional recovery is incomplete and parts of the myocardium remain hypoperfused. In this randomized, placebo-controlled, and double-blinded study, we investigated relative changes in myocardial perfusion and glucose metabolism induced by intracoronary administration of blood-derived circulating progenitor cells (CPCs)...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید