نتایج جستجو برای: دستگاه pentacam

تعداد نتایج: 31547  

Journal: :journal of current ophthalmology 0
عباسعلی یکتا abbas-ali yekta حسن هاشمی hassan hashemi مهدی خبازخوب mehdi khabazkhoob اصغر دوستدار asghar dostdar شیوا مهرآوران shiva mehravaran جواد هرویان javad heravian اکبر فتوحی

purpose: to compare thickness of central cornea measured using pentacam, orbscan ii, and ultrasound pachymeter methods: patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. central corneal thickness (cct) was measured by three metho...

Journal: :Journal of refractive surgery 2010
Giacomo Savini Kenneth J Hoffer

Journal: :بینا 0
علیرضا برادران رفیعی ar baradaran rafii ocular tissue engineering research center, shahid beheshti university of medical sciences, tehran, iranمرکز تحقیقات مهندسی بافت چشم- دانشگاه علوم پزشکی شهید بهشتی- تهران- ایران تهمینه متوسلی t motevasseli shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران فروزان یزدی زاده f yazdizadeh بیمارستان اروند- دانشگاه علوم پزشکی اهواز- اهواز- ایران شبنم انصاری sh ansari shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران فرید کریمیان f karimian shahid beheshti university of medical sciencesمرکز تحقیقات چشم- دانشگاه علوم پزشکی شهید بهشتی- تهران- ایران محمدمهدی صدوقی mm sadoughi shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران حسین کیانی

baradaran rafii ar, md; motevasseli t, md*; yazdizadeh f, md; ansari sh, md; karimian f, md; sadoughi mm, md; kiani h ocular tissue engineering research center, shahid beheshti university of medical sciences, tehran, iran * corresponding author: [email protected] purpose: to compare anterior segment indices measured by two scheimpflug camera; galilei and pentacam. methods: in this observa...

2009
Rajeev Jain SPS Grewal

Rotating Scheimpflug imaging technology is used by instruments such as the Pentacam (Oculus) to measure the anterior and posterior corneal surfaces, as well as other anterior segment structures. Initially, Scheimpflug photography was used to obtain images of lens opacities for objective evaluation, but Pentacam-Scheimpflug camera is much wider in its clinical applications as a diagnostic tool f...

Journal: :journal of current ophthalmology 0
حسن هاشمی hassan hashemi عباسعلی یکتا abbasali yekta هادی استادی مقدم hadi ostadimoghaddam رضا نوروزی راد reza norouzirad مهدی خبازخوب mehdi khabazkhoob

purpose: to compare orbscan ii and pentacam keratometry readings in terms of their agreement with a manual javal type keratometer methods: in this retrospective study, records of patients who had refractive surgery were reviewed. we extracted data of 765 eyes which had keratometry with the javal keratometer of these, 577 had orbscan ii and 200 eyes had pentacam acquisitions. minimum (min-k) and...

Journal: :Current Journal of Glaucoma Practice with DVD 2009

Journal: :Acta Ophthalmologica 2022

Purpose: This study examines agreement between the devices Anterion® and Pentacam HR® used for corneal pupil measurements in healthy eyes. Methods: The parameters compared two were: anterior Km (D), K2 K1 axis (°), astigmatism K max posterior CCT (μm), thinnest point thickness X-coordinate (mm), Y-coordinate diameter center-corneal vertex distance (mm) (angle kappa), centroid angle (mm). Result...

Journal: :Journal of refractive surgery 2009
Jack T Holladay Warren E Hill Andreas Steinmueller

PURPOSE To evaluate the accuracy of central corneal power measurements by Scheimpflug imaging (Pentacam) for eyes that had corneal refractive surgery. METHODS This study comprised two groups: a pilot group of 100 eyes with prior hyperopic or myopic LASIK that did not have cataract surgery, and a test group of 41 eyes with prior radial keratotomy (RK) and cataract surgery. In the pilot group, ...

Journal: : 2023

قدرت تفکیک دستگاه طیف‌نگار جرمی به صورت مستقیم شدت یون خروجی و انرژی آن بستگی دارد. مقدار تولید شده جریان باریکه الکترونی وابسته است. از جمله وظایف مدار کنترل چشمه برخورد تنظیم برای رسیدن بهینه می‌باشد. در ساخت پارامترهایی نظیر تثبیت آن، دقیق پتانسل الکتریکی لنز الکترودهای یونی بسیار حایز اهمیت این مقاله با قابلیت انتشار الکترون، پتانسیل نقاط طراحی ساخته شد. کنترلر بر روی طیف نگار 44Varian MAT ...

2008
Satinder Pal S. Grewal

Primary angle-closure glaucoma (PACG) is a major form of glaucoma in Asia. It is a leading cause of blindness worldwide. Laser peripheral iridotomy (LPI) is the standard firstline intervention in both acute and chronic forms. It is successful in preventing recurrence of acute attacks and virtually eliminates the risk of an acute attack in the fellow eye. Peripheral iridotomy eliminates pupillar...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید