نتایج جستجو برای: ventilator

تعداد نتایج: 11312  

Journal: :Zhonghua yi xue za zhi = Chinese medical journal; Free China ed 2001
T C Lien M Y Lin C C Chu B I Kuo E D Wang J H Wang

BACKGROUND Frequent ventilator circuit changes are expensive and sometimes unnecessary. Following the worldwide trend to lengthen the intervals for ventilator circuit change from 2 days to 1 week, this study aims to assure that low rate of ventilator-associated pneumonia (VAP) can be maintained with cost containment. METHODS Ventilator circuits were routinely changed every 7 days in the study...

Journal: :iranian journal of nursing and midwifery research 0
hojatollah yousefi farzaneh toghyani ahmad reza yazdannik kamran fazel

a bstract background: mechanical ventilation is one of the supporting treatments that are used for different reasons. to reduce patients’ inconvenience caused due to using tracheal tube and ventilator, sedation is routinely used. using scales for the sedation, for example, richmond agitation sedation scale (rass), may reduce dose of sedation and length of mechanical ventilation.   materials and...

Journal: :Artificial intelligence in medicine 1993
Geoffrey Rutledge George E. Thomsen Brad R. Farr Maria A. Tovar Jeanette X. Polaschek Ingo A. Beinlich Lewis B. Sheiner Lawrence M. Fagan

VentPlan is an implementation of the architecture developed by the qualitative-quantitative (QQ) research group for combining qualitative and quantitative computation in a ventilator-management advisor (VMA). VentPlan calculates recommended settings for four controls of a ventilator by evaluating the predicted effects of alternative ventilator settings. A belief network converts clinical diagno...

Journal: :British journal of anaesthesia 1995
A McCluskey C L Gwinnutt

The performance of the Pneupac Ventipac portable gas-powered ventilator was evaluated in two stages. The accuracy of delivery of the ventilator was assessed using a mechanical lung model at different combinations of compliance and airway resistance to simulate normal and diseased lungs. The performance of the ventilator was then assessed in 20 anaesthetized patients. The tidal volume delivered ...

Journal: :Dimensions of critical care nursing : DCCN 2010
Rachel Scherzer

Ventilator-associated pneumonia is a common nosocomial infection that results in both negative patient outcomes and increased health care costs. Recently, many efforts have been targeted at ventilator-associated pneumonia prevention, including the practice of subglottic secretion aspiration. Six randomized control studies examining the effectiveness of subglottic secretion aspiration in the pre...

2017
Guillaume Mortamet Alexandrine Larouche Laurence Ducharme-Crevier Olivier Fléchelles Gabrielle Constantin Sandrine Essouri Amélie-Ann Pellerin-Leblanc Jennifer Beck Christer Sinderby Philippe Jouvet Guillaume Emeriaud

BACKGROUND We aimed (1) to describe the characteristics of patient-ventilator asynchrony in a population of critically ill children, (2) to describe the risk factors associated with patient-ventilator asynchrony, and (3) to evaluate the association between patient-ventilator asynchrony and ventilator-free days at day 28. METHODS In this single-center prospective study, consecutive children ad...

Journal: :Anaesthesia 1983

Journal: :Historical Studies in the Natural Sciences 2021

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید