نتایج جستجو برای: varian linac

تعداد نتایج: 5259  

2008
Ye Angela Hu Haijun Song Zhe Chen Sumin Zhou Fang‐Fang Yin

The electron Monte Carlo (eMC) dose calculation algorithm of the Eclipse treatment planning system is based heavily upon Monte Carlo simulation of the linac head and modeling of the linac beam characteristics with minimal measurement of beam data. Commissioning of the eMC algorithm on multiple identical linacs provided a unique opportunity to systematically evaluate the algorithm with actual me...

Journal: :Medical physics 2012
J Tan H Li P Parikh E Izaguirre D Yang

PURPOSE Longitudinal coverage of CBCT, which is 17 cm for head scan and 15.5 cm for body scan, is not enough to cover the entire PTV for over 90% of head/neck and gastrointestinal/genitourinary/gynecologic patients if lymph nodes are involved. Helical CBCT, which was accomplished using external beam LINAC in its research mode, is one promising way to extend the CBCT longitudinal coverage. Aim o...

2015
Maria F. Chan Qiongge Li Xiaoli Tang Xiang Li Jingdong Li Grace Tang Margie A. Hunt Joseph O. Deasy

Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon energies and five electron energies was commissioned in early 2010. Daily Linac QA tests including the output constancy, beam flatness and symmetry (radial and transverse direction...

Journal: :Medical physics 2012
L Bartol L DeWerd

PURPOSE Effective treatment planning for radiotherapy is dependent on accurate spectra determination; however, direct measurements of spectra arecomplicated by fluence rates that exceed detection system limitations. This work demonstrates the potential to use a Compton scattering technique to measure the spectrum of a 6MV linac. These spectra are further characterized using Monte Carlo (MC) sim...

Journal: :jentashapir journal of health research 0
mohammad javad tahmasebi birgani department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran mansour zabihzadeh department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; student research committee, ahvaz jundishapur university of medical sciences, ahvaz, ir lran; department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran. tel: +98-9125032283 sholeh arvandi department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran elahe gharibreza department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran

conclusions using the maximum dose depth from pdd curves and the inverse square law, the required ssdeff to calculate the dose distribution of the electron beam can be calculated. objectives the aim of this study was to determine the effective source-surface distance (ssdeff) of an electron linear accelerator (linac), and its dependence on energy and depth. materials and methods a varian linac ...

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2021

Introduction: Radiotherapy is one of the important treatment modalities in cancer treatment. To maintain procedure accuracy, phantom an essential tool for absolute dosimetry conformation and Quality Assurance routine cheek up. This work aims to study absorbed dose various phantoms hence make a comparison result with IAEA recommendation (TRS 398) daily QA Linac. Materials Methods: The experiment...

Introduction: One of the concerns about using of high energy photons in radiotherapy is neutron contamination production. The threshold energy of photoneutron production in most materials with high atomic number is about 7MeV. Therefore, it seems to be logical that the main components with high atomic number elements used in the LINAC head have a large contribution to the neutr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید