نتایج جستجو برای: steel frame with divergent bracing
تعداد نتایج: 9282006 فیلتر نتایج به سال:
run-out-table (rot) is located between last finishing stand and down coiler in a hot strip mill. as the hot steel strip passes from rot, water jets impact on it from top and bottom and strip temperature decreases approximately from 800-950 °c to 500-750°c. the temperature history that strip experience while passing through rot affects significantly the metallurgical and mechanical properties, s...
concentric bracing is one of the most common lateral load resistant systems in building frames, and areapplied to many structures due to their manufacturing simplicity and economics. an important deficiency in thebracing members is their irregular hysteretic loops under cyclic loading. in order to overcome this problem, it isadvised to restrain braces against buckling under compression, since b...
dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. these walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. in this research intermediate dual system of steel moment frame was chosen with int...
Steel Special Moment Frames (SMFs) are favored seismic force-resisting systems due to their architectural flexibility and high ductility. While shallow columns (section depth less than 356 mm) were commonly used in these before the Northridge earthquake, deeper greater have become more popular recent years meet code-enforced story drift requirements economically. However, limited research exist...
Nowadays, with the increase of the terrorist attacks around the urban places, the building design under the blast loadings is of primary considerations, especially for some important buildings and vital arteries. When an explosion occurs, the blast waves can cause severe damage to the structure and endanger the lives of people. Since the existing steel structures are usually designed for the ty...
In the present paper, the focus is on the evaluation of steel dual-system frame buildings using four main types of structural analysis (Linear Static, Linear Dynamic, Nonlinear Static and Nonlinear Dynamic Analyses) with regard to "Seismic Rehabilitation Code for Existing Buildings in Iran" (based on FEMA 273 and 356) where the first two authors of the article tend to follow the previous work (...
steel structures are usually built with some defects. according to the standard building codes, the central axes of the bracing members should go through the beam-column joints, however, in most of the braced steel structures, bracing members are unintentionally connected eccentrically. this paper presents a numerical investigation on performance analysis of cbfs (concentrically braced frames) ...
Spacious experimental and numerical investigation has been conducted by researchers to increase the ductility and energy dissipation of concentrically braced frames. One of the most widely used strategies for increasing ductility and energy dissiption, is the use of energy-absorbing systems. In this regard, the cyclic behavior of a chevron bracing frame system equipped with multi-pipe dampers (...
Seismic excitation can cause significant energy to be released within structures. By using special devices, this consumed and dissipated without deforming structural members significantly. Due this, damage is minimized, casualties are prevented during earthquakes, structures extended in their useful life. Over the past five decades, it has been widely acknowledged that steel yielding dampers am...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید