نتایج جستجو برای: stabilizer control
تعداد نتایج: 1333772 فیلتر نتایج به سال:
This paper proposes a robust control framework for power system stabilizer to improve system dynamic performance based on model predictive control (MPC). The effectiveness of the proposed power system stabilizer is validated by a simple power system composed of a synchronous generator connected to an infinite bus through a transmission line. A comparison between power system responses at variet...
INTRODUCTION Lack of efficacy of pharmacotherapy and physiotherapy in spinal pain syndrome is an indication for intervertebral stabilizer implantation between the processes in the lumbar segment of the spine. MATERIAL AND METHODS The group consisted of 32 patients qualified after radioisotopic single-photon emission computed tomography/computed tomography (SPECT/CT) examinations with assessme...
We study control systems where the output subspace is covered by a finite set of quantization regions, and the only information available to a controller is which of the quantization regions currently contains the system’s output. We assume the dimension of the output subspace is strictly less than the dimension of the state space. The number of quantization regions can be as small as 3 per dim...
Power systems are subjected to low frequency disturbances that might cause loss of synchronism and an eventual breakdown of entire system. The oscillations, which are typically in the frequency range of 0.2 to 3.0 Hz, might be excited by the disturbances in the system or, in some cases, might even build up spontaneously. These oscillations limit the power transmission capability of a network an...
The effect of time delay is very important for the consideration of stability of a generator excitation control system. Measurement devices, communication links used for data transfer are responsible for the significant time delays. This paper presents the effect of time delays on the stability of generator excitation control system. The maximum amount of time delay known as delay margin is det...
This paper addresses a robust fuzzy controller to damp low frequency oscillation following disturbances in power systems. In this research the fuzzy controller is used as a Power System Stabilizer (PSS) to improve the stability in power system. The rule base of the proposed PSS is optimized offline automatically by the improved Genetic Algorithm (GA). Usually in a rule base fuzzy control system...
Off-pump Coronary Artery Bypass Grafting (CABG) is still a technically difficult procedure. The mechanical stabilizers used for local suppression of the heart excursion have been demonstrated to exhibit significant residual motion, which could lead to a lack of accuracy in performing the surgical task, particularly when using a minimally invasive surgery (MIS) approach. We therefore propose a n...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید