نتایج جستجو برای: slab method

تعداد نتایج: 1638307  

Journal: :Magnetic resonance in medicine 2010
Peng Hu Michael L Chuang Kraig V Kissinger Beth Goddu Lois A Goepfert Neil M Rofsky Warren J Manning Reza Nezafat

We propose a non-contrast-enhanced, three-dimensional, free-breathing, electrocardiogram-gated, gradient recalled echo sequence with a slab-selective inversion for pulmonary vein (PV) MRI. A sagittal inversion slab was applied prior to data acquisition to suppress structures adjacent to the left atrium (LA) and PVs, thereby improving the conspicuity of the PV and LA. Compared with other MR angi...

2013

Reinforced concrete stair slabs with mid landings i.e. Dog-legged shaped are conventionally designed as per specifications of standard codes of practices which guide about the effective span according to the varying support conditions. Presently, the behavior of such slabs has been investigated using Finite Element method. A single flight stair slab with landings on both sides and supported at ...

2004
Brian A. Hargreaves Charles H. Cunningham Dwight G. Nishimura Steven M. Conolly

Figure 3. Coronal (top) and axial (bottom) views from a 3D acquisiton slightly above the heart. Images have 2x2x3 mm resolution. The coronal image shows the 4cm, TB=10 slab profile in vivo. The contrast is consistent across the slab, indicating a flat slab profile. The black level is 0 for these images. Introduction: Balanced steady-state free precession (SSFP) imaging (TrueFISP, FIESTA, balanc...

1999
Nabeel Murshed

A new method for detecting one-pixel wide vertical, horizontal and diagonal line segments in binary images, is presented. It is based on using four slabs of neural networh, each of which is composed of a set layers. Each layer consists of a number of neurons that is determined by the slab type. The whole image is used as input to each slab, and the infomation processing in each slab occurs in p...

Abstract The liquid crystal director distribution is determined for a confined chiral nematic slab. The molecular director distribution of the field-controlled chiral nematic slab is directly calculated. The director profiles for the tilt and the twist angles, under different applied fields, are calculated in the slab with weak boundary conditions. Then, the dependence of the threshold field on...

2016
Aaron P. Krause

This research investigates the development and evaluation innovative methods for the use of conductive concrete as an electromagnetic shield. New testing methods are developed to determine the best conductive components to use in the design of a concrete mixture for shielding that shows the best promise. The conductive concrete mixture has the potential to provide electromagnetic shielding that...

2013
Mustafa Basheer Mahmood V. C. Agarwal Sam Higginbottom

The present study deals with the finite element modelling of control RC slabs and strengthened slabs with the help of ANSYS. ANSYS is software that is based on FE method in which modelling of RC structures is done. In this study, a control slab was modelled and the results were analysed and then strengthened slabs were modelled and analysed. The results of the control and strengthened slabs wer...

F. Farhat-Nia and M. Salimi,

In this paper, an analytical method based on Modified Slab Method of analysis is presented to study the asymmetrical rolling process due to difference in work rolls radii, rolls speeds and interface frictions. The shear force imposed on material along the contact region is considered to be a function of the frictional factor and the roll gap geometry. Elastic-plastic with linear work hardening ...

Journal: :IEICE Transactions 2014
Naofumi Kitsunezaki

We calculated propagation constants of supermodes for two-dimensional two-slab waveguides, with small core gap, using secondorder perturbation expansion from gapless slab waveguide system, and compared our results with the existing works. In the perturbation calculation, we used trapezoidal method to calculate the integral over the transverse direction in space and obtained second-order expansi...

2016
P. Olmati

Flat slab concrete buildings are widely found in infrastructure such as office and residential buildings or industrial facilities. The susceptibility of progressive collapse of such structures due to accidental loads is highly dependent on the structural performance of the slab-column connections. This paper presents a framework for a simplified reliability analysis and derivation of safety fac...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید