Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology.Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the ab...
introduction: skin sparing is one of the most desirable characteristics of high energy photon beams. however, the photons emerging from the target of linacs are contaminated by secondary electrons as a result of their interactions with air, collimators, flattening filter and any other objects in their path. this phenomenon tends to increase the skin dose received b...
BACKGROUND Tumor Treating Fields (TTFields) are an anti-neoplastic treatment modality delivered via application of alternating electric fields using insulated transducer arrays placed directly on the skin in the region surrounding the tumor. A Phase 3 clinical trial has demonstrated the effectiveness of continuous TTFields application in patients with glioblastoma during maintenance treatment w...
The Thermal Diffusion Probe 200 (TDP200) is a thermal properties characterization device that is capable of measuring the thermal conductivity of phantom materials with less than 0.2% variability. However, this device gives 1.5% to 2% variability in thermal conductivity values when the medium being measured is human skin tissue. Six different sources of variability have been identified that mig...
Cryogen spray cooling (CSC) is a heat extraction process that protects the epidermis from thermal damage during dermatologic laser surgery. The objective of the present work is to investigate radial and temporal variations in the heat transferred through the surface of a skin phantom during CSC. A fast-response thermal sensor is used to measure surface temperatures every 1 mm across a 16 mm dia...
INTRODUCTION In this study, we intend to use diffuse optical Tomography (DOT) as a noninvasive, safe and low cost technique that can be considered as a functional imaging method and mention the importance of image reconstruction in accuracy and procession of image. One of the most important and fastest methods in image reconstruction is the boundary element method (BEM). This method is introduc...
Reorganization of motor and somatosensory cortex in upper extremity amputees with phantom limb pain.
Phantom limb pain (PLP) in amputees is associated with reorganizational changes in the somatosensory system. To investigate the relationship between somatosensory and motor reorganization and phantom limb pain, we used focal transcranial magnetic stimulation (TMS) of the motor cortex and neuroelectric source imaging of the somatosensory cortex (SI) in patients with and without phantom limb pain...
An anthropomorphic phantom was used to investigate a treatment technique and analyze the dose distributions for helical irradiation of the total skin (HITS) by helical tomotherapy (HT). Hypothetical bolus of thicknesses of 0, 10, and 15 mm was added around the phantom body to account for the dose homogeneity and setup uncertainty. A central core structure was assigned as a "complete block" to f...
PURPOSE To compare radiation dose and image quality between a slot-scanning system (SSS) and a dynamic flat-panel detector (DFD) in assessing scoliosis in children. METHODS An experimental study was first performed with a phantom to assess the quality of each device. The clinical part included a prospective observational dosimetric and qualitative comparative study with acquisition of whole-s...
We report our technique for hemibody skin electron irradiation with a custom-made plywood shield. The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a plywood shield placed at 50 cm from the patient. The shield is made of three laye...