نتایج جستجو برای: sife eldeen dosimeter

تعداد نتایج: 2155  

Journal: :Journal of Physics: Conference Series 2022

Abstract In vivo dosimetry for patient radioprotection is a real challenge concerning new radiotherapy treatments. this study we aim to develop dosimeter based on tissue equivalent material, flexible and adaptable the morphology in order perform complex irradiation beams. Here, report evaluation standard beams of highly composed silicone elastomer containing leucomalachite green as radiochromic...

Journal: :Pertemuan dan Presentasi Ilmiah Standardisasi 2021

2013
Schouten

A practical exercise for developing a simple cost-effective solar ultraviolet radiation dosimeter is presented for use by middle school science students. Specifically, this exercise investigates a series of experiments utilising the historical blue print reaction, combining ammonium iron citrate and potassium hexacyanoferrate to develop an ultraviolet sensitive solution. The activity is intende...

2014
Yusuke Koba Kiyomitsu Shinsho Satoshi Tamatsu Shigekazu Fukuda Genichiro Wakabayashi

In order to measure a three-dimensional dose distribution in X-ray radiotherapy, we developed TL slab dosimeter with new TL phosphor Li3B7O12(Cu), which has Zeff = 7.42 and a density of 1.01 g/cm 3 and synthetic resin as binder [1].We can measure a three-dimensional dose distribution easily and reliably using this detector. This detector showed a promising tool for QA/QC in advanced X-ray radio...

Journal: :The European respiratory journal 2002
R J Ward C Ward D P Johns B Skoric M Abramson E H Walters

Two potential sources of systematic variation in output from Mefar dosimeters, the system used in the European Community Respiratory Health Survey (ECRHS) study have been evaluated: individual nebulizer characteristics and dosimeter driving pressure. Output variation from 366 new nebulizers produced in two batches for the second ECRHS were evaluated, using a solute tracer method, at a fixed dri...

Journal: :Molecules 2013
Shu-Kun Lin

We have been made aware of the fact that a large proportion of the Introduction section and corresponding references of the title paper [1] had been copied verbatim from an earlier paper by Hamdy and Gamal-Eldeen [2], and further, during our investigation it has also come to light that most of the text in question had been lifted unchanged from an even earlier review paper by a different group ...

2011
Timothy Olding Oliver Holmes Paul DeJean Kim B. McAuley Ken Nkongchu Giles Santyr L. John Schreiner

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

2014
A Asena T Kairn S B Crowe S T Smith

This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for atte...

2015
Hyesu Jeon Wook Jae Yoo Sang Hun Shin Guwon Kwon Mingeon Kim Hyejin Kim Young Beom Song Kyoung Won Jang Won Sik Youn Bongsoo Lee

We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber...

2014
S. M. Gafar

In this study the spectrophotometric response of the Toluidine Blue O (TBO)-gelatin gel dosimeter irradiated with gamma rays was characterized. Preparation of dyed-gelatin gel takes place in neutral medium; to give eventually gel dosimeter has a sharp absorbance peak at 635 nm that bleaches quantitatively upon irradiation and the colour change can be measured with UV-VIS spectrophotometer. The ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید