نتایج جستجو برای: shower cooling tower
تعداد نتایج: 66769 فیلتر نتایج به سال:
Natural and engineered water systems are the main sources of Legionnaires' disease. It is essential from a public health perspective to survey water environments for the existence of Legionella. To analyze the main serogroups, genotypes and pathogenicity of the pathogen, a stratified sampling method was adopted to collect water samples randomly from shower water, cooling tower water, and local ...
A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8 radiation lengths to sample the initial development of the shower. Results concerning energy resolution, impact point reconstruction and e/π separation are repo...
A fluorescence telescope tower array has been designed to measure cosmic rays in the energy range of 10(17)-10(18) eV. A full Monte Carlo simulation, including air shower production, light generation and propagation, detector response, electronics, and trigger system, has been developed for that purpose. Using such a simulation tool, the detector configuration, which includes one main tower arr...
An updraft tower cooling system is assessed for elimination of water use associated with power plant heat rejection. Heat rejected from the power plant condenser is used to warm the air at the base of an updraft tower; buoyancy-driven air flows through a recuperative turbine inside the tower. The secondary loop, which couples the power plant condenser to a heat exchanger at the tower base, can ...
in this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. a polyamide spiral wound ro membrane followed by three filters as ro pretreatment (two activated carbon and one cartridge filter) and samples of tehran refinery treated waste water have been used. the effect of operating conditions such as pressure difference...
In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...
A cooling water system is used in industrial processes to cool down hot process streams from their supply conditions to target temperatures. A cooling water system is comprised of three major components, namely a cooling tower, a heat exchanger network (HEN), and a pumping system; these elements have strong interactions with each other and therefore must be optimized simultaneously to yield an ...
Traditionally, energy recommendations from energy audits have been concerned with the energy use of cooling towers for point of use energy, such as variable speed fans, and pumping savings. The actual energy use of a cooling tower is small, and is only a portion of the energy involved in the entire cooling system. The majority of the energy used is to perform the work necessary to compress the ...
The aim of the current study is to develop a numerical tool that is capable of achieving an optimum shape and design of hyperbolic cooling towers based on coupling a non-linear finite element model developed in-house and a genetic algorithm optimization technique. The objective function is set to be the minimum weight of the tower. The geometric modeling of the tower is represented by means of ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید