نتایج جستجو برای: scatter collimator factor

تعداد نتایج: 857363  

ژورنال: کومش 2020

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

Journal: :Physics in medicine and biology 2010
J L Ducote S Molloi

X-ray scatter is a major cause of nonlinearity in densitometry measurements using digital mammography. Previous scatter correction techniques have primarily used a single scatter point spread function to estimate x-ray scatter. In this study, a new algorithm to correct x-ray scatter based on image convolution was implemented using a spatially variant scatter point spread function which is energ...

2013
Hisayuki Miyashita Shogo Hatanaka Yukio Fujita Shimpei Hashimoto Atsushi Myojyoyama Hidetoshi Saitoh

Output factor (Scp) is one of the important factors required to calculate monitor unit (MU), and is divided into two components: phantom scatter factor (Sp) and in-air output ratio (Sc). Generally, Sc for arbitrary fields are calculated using several methods based on Sc determined by the absorbed dose measurement for several square fields. However, there are calculation errors when the treatmen...

2012
Tuija Kangasmaa Jyrki Kuikka Antti Sohlberg

Simultaneous Tl-201/Tc-99m dual isotope myocardial perfusion SPECT is seriously hampered by down-scatter from Tc-99m into the Tl-201 energy window. This paper presents and optimises the ordered-subsets-expectation-maximisation-(OS-EM-) based reconstruction algorithm, which corrects the down-scatter using an efficient Monte Carlo (MC) simulator. The algorithm starts by first reconstructing the T...

Journal: :Analytical chemistry 2002
Katharina Baur Sean Brennan Piero Pianetta Robert Opila

Figure 1. TXRF spectrum of a clean Si wafer surface showing 6.4x10 atoms/cm Fe and 2.6x10 atoms/cm Cu. The Cl is a residue from the HCl solution used to clean the wafer surface and the Ag is a artifact from the particular collimator used in these studies. Other features seen in the spectrum are the Si substrate peak, the scatter peak at 11.2 keV and the escape peak at 9.4 keV. Looking at Trace ...

Journal: :Nuclear Engineering and Technology 2021

In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and air filter, was developed. A collimator applied to the system showed enhancement in resolution degradation efficiency. The efficiency were compared analyzed evaluate performance collimator. Thus, found be more important than as determining factor performance, from viewp...

2017
Shinro Matsuo Kenichi Nakajima Koichi Okuda Masaya Kawano Takehiro Ishikawa Tetsuo Hosoya Seigo Kinuya

Background. Although heart-to-mediastinum (H/M) ratio in a planner image has been used for practical quantification for I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of H/M can be standardized to the various types of camera-collimator combinations. Methods and Results. Standard phantoms consisting of the heart, ...

Journal: :Physics in medicine and biology 2007
Predrag Marinkovic Radovan Ilic Rajko Spaic

A three-dimensional (3D) point-kernel multiple scatter model for point spread function (PSF) determination in parallel-beam single-photon emission computed tomography (SPECT), based on a dose gamma-ray buildup factor, is proposed. This model embraces nonuniform attenuation in a voxelized object of imaging (patient body) and multiple scattering that is treated as in the point-kernel integration ...

Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...

2016
Mukesh N. Meshram Srimanta Pramanik C.P. Ranjith Saravana K. Gopal Rishabh Dobhal

This study presents the basic dosimetric properties of photon beams of a Versa HD linear accelerator (linac), which is capable of delivering flattening filter-free (FFF) beams with a beam quality equivalent to the corresponding flattened beams based on comprehensive beam data measurement. The analyzed data included the PDDs, profiles, penumbra, out-of-field doses, surface doses, output factors,...