نتایج جستجو برای: ray film
تعداد نتایج: 386512 فیلتر نتایج به سال:
Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown...
In this paper, ZnO thin film is deposited on slide glass substrate using the sol-gel process. Presenting well-defined orientation of ZnO thin films Nanostructure were obtained by dip coating of zinc acetate dihydrate, monoethanolamine (MEA), de-ionized water and isopropanol alcohol. The annealed ZnO thin films were transparent ca 85-90% in visible range with an absorption edges at about 375 nm....
METHOD A 14" X 17" Kodak Industrial x-ray film, type M, is placed on a smooth surface in a darkroom. The original photoscan is superimposed on this film, and then both covered with a 15" X 18" glass plate, one-fourth inch thick, and exposed to an incadescent bulb for a very short period of time, 0.5-2.0 seconds. The ex posed film is developed and a negative picture is obtained. The contrast on ...
An immunologically deficient patient had two large nodular densities on the chest x-ray film. On autopsy, large solid accumulations and diffuse pneumonitis with Pneumocystis carinii were found. This represents an unusual manifestation of Pneumocystis carinii.
Traditionally in the United States, large size chest x-ray film examinations are made with 14 x 17 inch ifims in 15 x 18 inch cassettes. When a survey minifilm reveals a questionable disease process, large films are ordered for further study. This film has become the accepted size through years of routine practice. Its use is habitual and specified in practically all hospitals, clinics and doct...
We developed a new method for characterizing molecular distribution in very thin liquid crystal layer (5–40 nm) evaporated onto rubbed polyimide film used by grazing-incidence X-ray diffraction (GIXD). The diffraction peaks corresponding to intermolecular correlation perpendicular to longitudinal axis of liquid crystal molecule and the clear anisotropic distribution of liquid crystal molecules ...
ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy. However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...
reduced graphene oxide film was synthesized on a glassy carbon electrode by electro reduction of graphene oxide powders in aqueous solution. then platinum nano particles were deposited on reduced graphene oxide film that was deposited on the glassy carbon electrode via electro reduction of platinum salt. the physical morphology of the platinum on reduced graphene oxide film was evaluated by sca...
carboxymethyl cellulose (cmc)-polyvinyl alcohol (pvoh) blend film, containing 0-10% cellulose nanowhiskers (cnw), was produced through casting method, while physical properties of the films being investigated. cmc-pvoh-cnw nanocomposites, were prepared with a diluted suspension of cellulose nanowhiskers. nanowhiskers suspension was prepared through acid hydrolysis of cotton linter by sulfuric a...
An x-ray-diffraction method that directly senses the phase of the structure factor is demonstrated and used for determining the local polarity of thin ferroelectric films. This method is based on the excitation of an x-ray standing-wave field inside the film as a result of the interference between the strong incident x-ray wave and the weak kinematically Bragg-diffracted x-ray wave from the fil...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید