نتایج جستجو برای: pressure relief valve
تعداد نتایج: 531950 فیلتر نتایج به سال:
background: the evaluation of prosthetic valves is very difficult with two-dimensional transthoracic echocardiography alone. doppler and color flow imaging as well as transesophageal echocardiography are more reliable to detect prosthetic valve dysfunction. however, doppler study sometimes tends to be misleading due to the load-depending characteristics of peak and mean pressure gradients. the ...
Nine patients with severe mitral disease were studied before and six months after mitral valve replacement with a three-cusp stented prosthesis using fresh autologous fascia lata tissue. Only patients in whom there was no auscultatory and angiographic evidence of incompetence of the replaced valve were selected for restudy. All patients claimed a marked improvement in their exercise capacity af...
A mathematical model is developed of a spring-loaded pressure relief valve connected to a reservoir of compressible fluid via a single, straight pipe. The valve is modelled using Newtonian mechanics, under assumptions that the reservoir pressure is sufficient to ensure choked flow conditions. The usual assumptions of ideal gas theory lead to a system of first-order partial differential equation...
Many surgical teams employ a sump pump to vent the left ventricle (LV). The problems associated with this technique are related to safety and convenience. If the flow is accidentally reversed in the LV vent line, air embolism accidents and subsequent litigation may be the result. If the cannula is occluded, it is inconvenient to juggle pump speed to prevent the line from collapsing while mainta...
Nine patients with severe mitral disease were studied before and six months after mitral valve replacement with a three-cusp stented prosthesis using fresh autologous fascia lata tissue. Only patients in whom there was no auscultatory and angiographic evidence of incompetence of the replaced valve were selected for restudy. All patients claimed a marked improvement in their exercise capacity af...
The China Fusion Engineering Test Reactor (CFETR), a superconducting magnetic confinement tokamak fusion reactor, will develop high-performance torus cryopump to pump plasma exhaust gas. inlet valve is one of the key components cryopump, and it used isolate from for regeneration, control pumping speed operate as pressure relief in case failure, such cryopipe breaking inside chamber. This paper ...
Prostheses are prescribed to restore the mobility of people with amputated lower limbs. Monitoring the prosthesis wearing times and physical activity of prosthesis users would provide invaluable information regarding rehabilitation progress and suitability of the prosthesis. The validation of a method to determine wearing times and physical activity state, as well as strides taken, of amputees ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید