نتایج جستجو برای: pregnancy heart valve prosthesis anticoagulants
تعداد نتایج: 630013 فیلتر نتایج به سال:
transcatheteraortic valve implantation, first introduced in 2002, has been established as an alternative modality for patients deemed not suitable for open-heart surgery. the anatomical vicinity of the atrioventricular node and the his bundle to the non-coronary and rightcoronary aortic cusps predisposes patients to conduction abnormalities in case of severe calcification or mechanical trauma d...
This report deals with a rare complication of disc-valve prosthesis in the mitral area. A significant disc poppet and struts destruction of mitral BeaU valve prostheses occurred 20 and 17 months after implantation. The resulting valve incompetence in the first case contributed to the death of the patient. The durability of Teflon prosthetic valves appears to be in question and this type of valv...
Thrombosis of mechanical heart valve prosthesis is a rare fatal complication after heart valve replacement. This report describes an old female patient with aortic prosthetic valve thrombosis who had a successful fibrinolytic treatment.
BACKGROUND As the prognosis of women with prosthetic heart valves improves, an increasing number are contemplating and undertaking pregnancy. Accurate knowledge of perinatal outcomes is essential, assisting counseling and guiding care. The aims of this study were to assess outcomes in a contemporary population of women with heart valve prostheses undertaking pregnancy and to compare outcomes fo...
BACKGROUND The purpose of this study is to examine the influence of the prosthesis type on early mortality and long-term survival after re-replacement of aortic valve prosthesis, especially in patients over 60 years old. METHODS Late outcome of 223 patients who underwent a reoperation on the aortic valve and received a mechanical (mechanical group) or biological (biological group) heart valve...
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...
Results 45.7% had successful pregnancy outcome. 40% cases had missed abortion. Five patients chose to have Medical Termination of Pregnancy (MTP) with tubal ligation. The majority of subjects (76.4%) delivered within 5 years of valve replacement. Despite counselling about embryopathy all except one patient continued to take oral anticoagulants. There was no maternal mortality. Morbidity in the ...
in recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. in this study the diameter of the aortic valve ring measured in 2-d echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. the purpos...
In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared with the implant of mechanical valves, it provides a more physiological haemodynamic performance and a reduced thrombogeneticity, avoiding the use of anticoagulants. The clinical outcomes of AVR are strongly...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید