نتایج جستجو برای: potentiometric sensors
تعداد نتایج: 96487 فیلتر نتایج به سال:
A new approach to potentiometric sensing utilizing paper-based microfluidic sampling is studied in this work. A solid-contact ion-selective electrode and a solid-contact reference electrode are pressed against a filter paper into which the sample solution is absorbed. The filter paper acts simultaneously as a sampling unit and as a sample container during potentiometric sensing. The paper subst...
A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline e...
Magnesium assays are being increasingly requested in hospitals and clinical research institutions. The ionized form of magnesium (iMg) is regarded as the biologically active fraction. Ionophore-based potentiometric sensors can determine iMg and apply a selectivity correction for co-existing interfering electrolytes, e.g. Ca 2+ . This technology has been used in several commercial blood analyzer...
The pH-sensitive chromoionophores brought the dream of the ion-selective membrane scientist close to realization. With the help of these molecules, one can build pH-sensitive, ion-selective electrodes and look into the bulk of solvent polymeric membranes during potentiometric measurements (spectropotentiometry) and image concentration profiles in situ with high spatial and temporal resolution. ...
Chapter 1. An Introduction to Fluorescent Zn(II) Sensors and Their Applications in Biological Systems This chapter opens with an overview of the numerous roles of zinc in biology, with an emphasis on labile Zn(II), that is, loosely bound or kinetically available stores of the ion. The synthesis, characterization, and application of fluorescent sensors for Zn(II) detection constitute an active f...
This work investigates the use of electronic tongues for environmental monitoring. Electronic tongue was based on arrays of potentiometric sensors plus a complex data processing by artificial neural networks. Special attention was paid in compensating temperature effects and possible drifts in the sensors response. In addition, and to demonstrate viability of the proposed systems for automated ...
Unlike the overwhelming majority of nanopore sensors that are based on the measurement of a transpore ionic current, here we introduce a potentiometric sensing scheme and demonstrate its application for the selective detection of nucleic acids. The sensing concept uses the charge inversion that occurs in the sensing zone of a nanopore upon binding of negatively charged microRNA strands to posit...
Construction and characterization of potentiometric membrane sensors for quantification of diclofenac and warfarin drugs are described. The membranes of the sensors incorporate 1.8 wt.% iron(II)-phthalocyanine (Pc) as a molecular recognition reagent, 64.3 wt.% dibutylsebacate (DBS) solvent mediator, 1.8 wt.% tridodecylmethylammonium chloride (TDMAC) as membrane additive and 32.1 wt.% poly(vinyl...
The construction and performance characteristics of new sensitive and selective in situ modified screen printed (ISPE) and carbon paste (ICPE) electrodes for determination of naphazoline hydrochloride (NPZ-HCl) have been developed. The electrodes under investigation show potentiometric response for NPZ-HCl in the concentration range from 7.0×10-7 to 1.0×10-2 M at 25 °C and the electrode respons...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید