Journal: :journal of biomedical physics and engineering 0
p mehnati ph.d., department of medical physics, school of medicine, tabriz university of medical sciences, tabriz, iran m jafari tirtash m.s. student, department of medical physics, school of medicine, tabriz university of medical sciences, tabriz, iran m ghavami department of radiology, school of medicine, tabriz university of medical sciences, tabriz, iran

normal 0 false false false en-us x-none ar-sa aim: ct number (hu) and linear attenuation coefficient contain useful information which  can be determined during usual ct scanning for the prediction of breast cancerous cells existence based on hemoglobin concentration. methods: this study used breast phantom containing major and minor vessels with diameters of 10 and 5 mm, respectively. the major...

Journal: :Sanitas 2022

CT number is one of the indicators in determining diagnosis disease, so it necessary to ensure level accuracy. The aim determine parameters kilovoltage and tube current value. Descriptive quantitative analytic research method with previously tested linearity suitability number. Furthermore, variation kilovoltage: 80kVp, 100kVp, 140kVp value 192mAs. After that, was continued: 80mAs, 100mAs, 140m...

2015
Susanne Ziegler Bjoern W. Jakoby Harald Braun Daniel H. Paulus Harald H. Quick

BACKGROUND In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

Journal: :iranian journal of radiation research 0
m.r. teimoori sichani department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran m. amoui department of nuclear medicine, shahid beheshti university of medical science, tehran, iran sh. akhlaghpoor noor medical imaging center, tehran, iran m. hosntalab department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

background: in this study, quantitative 32p bremsstrahlung planar and spect imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate dosimetry in clinical practice. materials and methods: ct, planar and spect bremsstrahlung images of jaszczak phantom containing a known activity of 32p were acquired. in addition, phanto...

2016
Nobuhiro Yada Hideo Onishi

OBJECTIVES In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC), using the bilinear scaling method. METHODS The measured attenuation coefficient (μm) was compared to the theoretical attenuation coefficient (μt), using four different CT scanners and an RMI 467 phantom. The effective energy of CT beam X-rays was calculated, using the alumin...

C.H. Xie, D.Z. Jiang, H. Liu, J. Zhang, X.T. Huang, Y.F. Zhou, Z.R. Bao,

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

2016
Reza Mahmoudi Nasrollah Jabbari Mehdi aghdasi Hamid Reza Khalkhali

INTRODUCTION For accurate dose calculations, it is necessary to provide a correct relationship between the CT numbers and electron density in radiotherapy treatment planning systems (TPSs). The purpose of this study was to investigate the energy dependence of measured CT numbers on substituted materials used for CT number calibration of radiotherapy TPSs and the resulting errors in the treatmen...

Journal: :iranian journal of radiation research 0
mahbod sedaghat department of medical physics, tehran university of medical sciences, tehran, iran m.h. zahmatkesh r. jaberi sh. akhlaghpoor m. allahverdi

abstractbackground: polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. in the current work, we present our preliminary results of investigating capability of x-r...

2013
Tsuyoshi Oguma Toyohiro Hirai Akio Niimi Hisako Matsumoto Shigeo Muro Michio Shigematsu Takashi Nishimura Yoshiro Kubo Michiaki Mishima

OBJECTIVES (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned...