نتایج جستجو برای: phantom ct ct number
تعداد نتایج: 1305532 فیلتر نتایج به سال:
normal 0 false false false en-us x-none ar-sa aim: ct number (hu) and linear attenuation coefficient contain useful information which can be determined during usual ct scanning for the prediction of breast cancerous cells existence based on hemoglobin concentration. methods: this study used breast phantom containing major and minor vessels with diameters of 10 and 5 mm, respectively. the major...
CT number is one of the indicators in determining diagnosis disease, so it necessary to ensure level accuracy. The aim determine parameters kilovoltage and tube current value. Descriptive quantitative analytic research method with previously tested linearity suitability number. Furthermore, variation kilovoltage: 80kVp, 100kVp, 140kVp value 192mAs. After that, was continued: 80mAs, 100mAs, 140m...
BACKGROUND In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements...
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
background: in this study, quantitative 32p bremsstrahlung planar and spect imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate dosimetry in clinical practice. materials and methods: ct, planar and spect bremsstrahlung images of jaszczak phantom containing a known activity of 32p were acquired. in addition, phanto...
OBJECTIVES In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC), using the bilinear scaling method. METHODS The measured attenuation coefficient (μm) was compared to the theoretical attenuation coefficient (μt), using four different CT scanners and an RMI 467 phantom. The effective energy of CT beam X-rays was calculated, using the alumin...
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...
INTRODUCTION For accurate dose calculations, it is necessary to provide a correct relationship between the CT numbers and electron density in radiotherapy treatment planning systems (TPSs). The purpose of this study was to investigate the energy dependence of measured CT numbers on substituted materials used for CT number calibration of radiotherapy TPSs and the resulting errors in the treatmen...
abstractbackground: polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. in the current work, we present our preliminary results of investigating capability of x-r...
OBJECTIVES (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید