نتایج جستجو برای: operation room

تعداد نتایج: 305942  

Journal: :Physical review applied 2023

We present all-electrical operation of a ${\mathrm{Fe}}_{x}{\mathrm{Cr}}_{1\ensuremath{-}x}$-based Curie switch at room temperature. More specifically, we study the current-induced thermally driven transition from ferromagnetic to antiferromagnetic Ruderman-Kittel-Kasuya-Yosida (RKKY) indirect coupling in ${\mathrm{Fe}/\mathrm{Cr}/\mathrm{Fe}}_{17.5}{\mathrm{Cr}}_{82.5}/\mathrm{Cr}/\mathrm{Fe}$...

چکیده: Background: Pain management in children is one of their rights and a treatment priority. This issue is considered as one of the accreditation standards in hospitals. Therefore, it is necessary to anticipate enhancement of pain management quality in hospital plans. This participatory action research (PAR) aimed to improve pain management in children under surgery. Methods: This qualitativ...

Journal: :journal of basic research in medical sciences 0
mahmood akhlaghi department of anesthesiology, faculty of medicine, shahrekord university of medical sciences, shahrekord, iran

anisocoria during anesthesia is very rare, but may indicate life-threatening neurologic injuries and create tremendous condition. a 23-year-old male patient was anesthetized with fentanyl and propofol. thirty minutes after inducing anesthesia, unilateral mydriasis was detected. the duration of surgery was shortened for prompt evaluation of the pupils. at the end of the operation neither vision ...

Journal: :مجله دانشگاه علوم پزشکی شهید صدوقی یزد 0
جمال حسین زاده j hossein zadeh . [email protected] محمدباقر خلیلی mb khalili محمدصادق گلوردی ms golvardi مریم ساده m sadeh محمد حسین صدر بافقی mh sadr-bafghi پری سیما محسنی میبدی ps mohseni- meybodi

introduction: many post-surgical wound infections in hospitals cause morbidity and morality of patients and these are usually transmitted via hands of surgical personnel. the aim of the present study was to detect and antibiogram the bacterial agents following scrubbing of hands of surgical personnel before operation. methods: hands of 134 personnels of operation room were swabbed following scr...

In this article, the design and modeling details of room-temperature analog-to-digital converter (ADC) based on silicon quantum-dot (QD) single-electron transistors (SETs) is presented. In contrast to the conventional metal quantum dots, the use of silicon QDs in the scales of few nano-meters enhances the device operation and makes stable the Coulomb blockade and Coulomb oscillation regimes at ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید