نتایج جستجو برای: normoxic polymer gel

تعداد نتایج: 197226  

2017
Heather M Whitney Daniel F Gochberg C Waldenberg A Karlsson Hauer

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

Journal: :Journal of Physics: Conference Series 2004

2009
A. Berg

Modern radiation techniques aim on improved 3-dimensional (3D) spatial selectivity of the dose application sparing dose from organs-at-risk (e.g. IMRT with micro-multileaf collimation, γ-knife-, Brachyand heavy-ion therapy). The corresponding 3D-dose distributions exhibit high dose gradients above 4 Gy/mm, which are difficult to be investigated using standard single-point dosimetric detectors ...

2013
M Mahdavi M KhademAbolfazli S-R-M Mahdavi Gh Ataei

BACKGROUND Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. OBJECTIVE The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. METHODS In this wor...

Journal: :Journal of Physics: Conference Series 2013

R. Jafari Khalilabadi, S. Aftabi, S.M. Abtahi,

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

2006
G. Gambarini D. Brusa M. Carrara G. Castellano M. Mariani M. Valente E. Vanossi

Abstract. Gel dosimeters are integrating dosimeters, that enable dose verification in three dimensions. Optical analysis of gel dosimeters has demonstrated to be an available technique for imaging the absorbed in-phantom dose exposed to radiotherapy beams. The goal is to demonstrate the ability of gel dosimeters to achieve accurately and spatial resolution in dose mapping, also when high dose r...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید