نتایج جستجو برای: negative impedance converter

تعداد نتایج: 592158  

2004
Marian K. Kazimierczuk

A6s t~ac t A flyback dc-dc converter is obtained from t h e conventional buck-boost converter by replacing t h e inductor with an isolation transformer. A transformer in the flyback converter is used to achieve a d c isolation between t h e input and the o u t p u t of t h e converter. This paper presents dc and small-signal circuit models for t h e flyback converter for continuous conduction m...

2011
C. Labarre

In this paper, we analyze the behaviour of a switched mode power supply (SMPS) regarding the radiated magnetic nearfield through an initial understanding of the electrical working of the converter, particularly during switchings. We propose a method based on impedance analysis at each state of the converter in order to predict the resonances of currents and/or voltages in the SMPS at the origin...

Journal: :CoRR 2017
Jing Lyu Qiang Chen Xu Cai Marta Molinas

The small-signal impedance modeling of modular multilevel converter (MMC) is the key for analyzing resonance and stability of MMC-based ac power electronics systems. MMC is a converter system with a typical multi-frequency response due to its significant steady-state harmonic components in the arm currents, capacitor voltages, and control signals. Therefore, traditional small-signal modeling me...

2004
Yungtaek Jang

Addition of an input filter to a current-programmed converter can cause the controller to oscillate. Two instability mechanisms can typically occur: 1) the current programmed controller effective current feedback loop may become unstable, or 2) the controller effective input voltage feed forward loop, which becomes a positive feedback loop when an input filter is added, may oscillate. Design cr...

and E. Afjei, F. Razavi, H.A. Abyaneh, R. Mohammadi H. Torkaman,

All algorithms for impedance calculation use an analog-to-digital converter. The high accuracy of the impedance seen by a distance relay is an important factor in the correct isolation of the faulty part of power systems. To achieve this, a novel&#10technique based on third order interpolation is used in this paper. According to this technique, the times and the values of the obtained samples a...

2014
Yam P. Siwakoti Poh Chiang Loh Frede Blaabjerg Graham E. Town

A new form of magnetically coupled DC/DC converter is proposed for medium power applications (250 W to 2 kW), requiring a high-voltage gain, short inductive charging time and galvanic isolation. The proposed converter can be realised using a unique Y-source impedance network and a two-switch push–pull circuit with voltage-doubling rectification. The converter’s voltage gain is presently not mat...

2014
S. AARTHI SURIYA A. SANTHI

In this paper, a high-efficiency fuel cell implemented by an LLC resonant dc–dc converter is proposed to save the cost and energy of fuel cell. The proposed converter has zero-voltage switching (ZVS) operation of the primary switches and zero-current switching (ZCS) operation of the rectifier diodes. By frequency modulation control, the output impedance of an LLC resonant converter can be regul...

2014
Michael Rapin Martin Proença Fabian Braun Josep Solà Pascal Olivier Gaggero Andy Adler Marc Correvon Olivier Chételat

Several studies [1,2] have shown the potential of EIT to estimate cardiovascular parameters. To achieve this goal, EIT devices have to deal with small impedance variations. As a consequence, the high value of the direct component (DC) of the bio-impedance signal becomes an issue in terms of analog to digital converter resolution. With this research, we aim at demonstrating that the DC of the si...

2014
F. Khoshkhati B. Asaei

This paper presents a power electronic interface converter based on asymmetric Γ-Source Inverter for photovoltaic application. The average state space model of the system is used for modeling of the proposed converter system. According to the obtained model of system, a two stage controller is designed to regulate the capacitor voltage of the impedance network to its required voltage and regula...

2010
T R Qureshi C R Chatwin Wei Wang

The current source is a key component in bio-impedance measurement systems. The accuracy of the current source can be measured in terms of its output impedance together with other parameters, with certain applications demanding extremely high output impedance. This paper presents an investigation and comparison of different current source designs based on the Enhanced Howland circuit combined w...

نمودار تعداد نتایج جستجو در هر سال