نتایج جستجو برای: narrow beam test
تعداد نتایج: 969196 فیلتر نتایج به سال:
We report a novel laser cavity design in third-order distributed feedback (DFB) terahertz quantum-cascade lasers based on a perfectly phase-matching technique. This approach substantially increases the usable length of the third-order DFB laser and leads to narrow beam patterns. Single frequency emissions from 151 apertures (5.6 mm long device) are coherently added up to form a narrow beam with...
Novel compact beam expanders that could be useful for applications such as providing light to flat panel displays are presented. They are based on a planar configuration in which three spatially linear gratings are recorded on one transparent substrate, so as to expand a narrow incoming beam in two dimensions. We present the design and recording procedures along with results, showing a relative...
We observe spectral hole burning in a room-temperature optical fiber pumped by a spectrally broadened pump beam. This beam drives the stimulated Brillouin process, creating an inhomogeneously broadened resonance in the material whose shape can be engineered by tailoring the beam's spectrum. A monochromatic saturating beam "burns" a narrow spectral hole that is approximately 10(4) times narrower...
Related Articles Design and test of a magnetic shield for turbomolecular pumps J. Vac. Sci. Technol. A 25, 1475 (2007) Removal of carbon deposits in narrow gaps by oxygen plasmas at low pressure J. Vac. Sci. Technol. A 25, 746 (2007) High temperature outgassing tests on materials used in the DIII-D tokamak J. Vac. Sci. Technol. A 24, 1572 (2006) Retention of neon in graphite after ion beam impl...
The scalar theory of the self-focusing of an optical beam is not valid for a very narrow beam, and a correct description of the beam behavior requires a vector analysis in this case. A vector nonparaxial theory is developed from the vector Maxwell equations by application of an order-of-magnitude analysis method. For the same input beam, the numerical results of self-focusing from both scalar a...
Animal models of locomotor recovery after brain injury provide tools for understanding the basic neurobiological processes that may underlie recovery after stroke in humans. Measurement of the ability of rats to traverse a narrow elevated beam has proven to be a particularly useful test of locomotor function. Repeated measurement of this behavior over time provides a simple method for quantifyi...
The lead equivalent of X-ray protective barriers are given for both concrete and steel for potentials between 200 an d 1,400 kv . These were determined experimentally u sing a pressure ion ization chamber and an ' _ray tube to which constant potential was applied. Narrow X-ray beam were used. The data obtained are compared with t ho e published by other workers. Data on the relat ive masses ref...
In this paper, we present a high accuracy laser range finder and velocimeter using ultra-fast time-to-digital converter (TDC). The system operation is based on the measuring the round-trip time of a narrow laser pulse. A low-dark current high-speed PIN photodiode is used to detect the triggered laser beam and to produce start signal. The pulsed laser diode generates 45W optical power at 30ns du...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید