OBJECTIVES IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in...
A collimator is often used to clean a beam of its excessive tail particles. If the beam intensity is high enough or if the beam is brought too close to the collimator, however, the wakefields generated by the beam-collimator interaction can cause additional beam tails to grow, thus defeating, or even worsening, the beam-tail cleaning process. The wakefield generated by a sheet beam moving past ...
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
For transmission computed tomography (TCT) systems using a centered transmission source with a fan-beam collimator, the transmission projection data are truncated. To achieve sufficiently large imaging field of view (FOV), we have designed the combination of an asymmetric fan-beam (AsF) collimator and a small uncollimated sheet-source for TCT, and implemented AsF sampling on a two-head SPECT sy...
The high beam intensities in the next linear collider can damage the collimation system jaws if a failure of the electronic machine protection system allows the acceleration of a mis-launched pulse. We are developing a prototype collimator that will allow a new jaw surface to be moved into place after beam damage. We are also developing a prototype collimator based on continuously reforming the...
We have calculated the dose enhancements close to metal implants in Gamma Knife radiosurgery using different beam sizes, i.e., 4, 8 and 18 mm collimator helmets sin addition to the previous calculations using the 14 mm collimator helmetd. For the 8 and 18 mm helmets, the obtained results were similar to those obtained using the 14 mm helmet, which can be explained by the similar beam profiles w...
In October 2009, a quad, mini-beam collimator was implemented at GM/CA CAT that allowed users to select between a 5, 10, or 20 micron mini-beam or a 300 micron scatter guard for macromolecular crystallography [1]. Initial alignment of each pinhole to the optical axis of each path through the mini-beam collimator is performed under an optical microscope using an alignment jig. Next, the pre-alig...
Algorithms have been developed for image reconstruction within a region-of-interest (ROI) from fan-beam data less than that required for reconstructing the entire image. However, these algorithms do not admit truncated data. In this work, we investigate exact ROI-image reconstruction from fan-beam data containing truncations by use of the so-called fan-beam backprojection-filtration (BPF) algor...
In this work, we developed and validated two novel imaging geometries of benchtop multi-pinhole X-ray fluorescence computed tomography (XFCT) systems with Geant4 Toolkit. One the Monte Carlo (MC) models utilized a fan beam source to illuminate single slice object, detector collimator image each slice’s (XRF). The other model consisted cone-beam (designed as 5 mm wide reduce simulation time) sca...
An empirical model for calculation of the collimator contamination dose in therapeutic proton beams.
Collimators are used as lateral beam shaping devices in proton therapy with passive scattering beam lines. The dose contamination due to collimator scattering can be as high as 10% of the maximum dose and influences calculation of the output factor or monitor units (MU). To date, commercial treatment planning systems generally use a zero-thickness collimator approximation ignoring edge scatteri...