نتایج جستجو برای: monte carlo code
تعداد نتایج: 236331 فیلتر نتایج به سال:
introduction the gamma knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. dose calculations required in the system are performed by gammaplan code; in this code, brain tissue is considered uniform. in the present study, we evaluated the effect of gamma knife system on the obtained dose through simulating a real h...
background: for an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. the usual method to determine these factors is thermo luminescent dosimeter (tld) dosimetry. nowadays, another more accurate method is known to be the monte carlo ...
introduction: secondary radiation such as photoelectrons, auger electrons and characteristic radiations cause a local boost in dose for a tumor when irradiated with an external x-ray beam after being loaded with elements capable of activating the tumor, e.g.; i and gd. materials and methods: in this investigation, the mcnpx code was used for simulation and calculation of dose enhancement facto...
To examine the domain decomposition of a coupled Monte Carlo nite element calculation, it is important to use a domain decomposition that is suitable for the individual models. We have developed a code that simulates a Monte Carlo calculation running on a massively parallel processor. This code is used to examine the load balancing behavior of three domain decomposition strategies for a Monte C...
We present the results in embedding a multigrid solver for Poisson's equation into the parallel 3D Monte Carlo device simulator, PMC-3D. First we have implemented the sequential multigrid solver, and embedded it into the Monte Carlo code which previously was using the sequential successive overrelaxation (SOR) solver. Depending on the convergence threshold, we have obtained signi cant speedups ...
Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید