نتایج جستجو برای: mono isocentric
تعداد نتایج: 19369 فیلتر نتایج به سال:
Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...
Phthalates are ubiquitous endocrine-disrupting chemicals that are contaminants in food and contribute to significant dietary exposures. We examined associations between reported consumption of specific foods and beverages and first trimester urinary phthalate metabolite concentrations in 656 pregnant women within a multicenter cohort study, The Infant Development and Environment Study (TIDES), ...
With conventional diagnostic X-ray machines with over couch X-ray tubes, it is not possible to obtain anteroposterior (AP) and lateral (Lat) radiographs without changing the posture of the patients. In an old 300 mA X-ray machine with a fluoroscopy screen (12.4 kg) (1995 model), by substituting the screen with suitable counterweight and making provision to take the hoist pillar up to the edge o...
The rapid synthesis of 4-aryl-2,2'-bipyridines is described leading to some previously reported compounds in good yields in addition to some new functionalized bipyridines.
External photon beam radiotherapy is usually carried out with more than one radiation beam in order to achieve a uniform dose distribution inside the target volume and an as low as possible a dose in healthy tissues surrounding the target. ICRU Report No. 50 recommends a target dose uniformity within +7% and –5% of the dose delivered to a well defined prescription point within the target. Moder...
the 2-mono and 2,6-disubstituted methyl-1,4-dihydropyridines were synthesized by reaction of morpholine, thiophenol, 8-hydroxyquinoline, 2-naphthol and 2-mercopto-1-methyl imidazole with the 2-mono bromo and 2,6-dibromo-1,4-dihidropyridines.
Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while the patient is treated. The DAVID system is a flat, multi-wire transmission-type...
background: a set of hardware stereotactic radiosurgery is designed and constructed. the scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 mv neptun 10 pc linac. materials and methods: one collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. beam data, suc...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید