نتایج جستجو برای: metal artifact

تعداد نتایج: 215918  

Journal: :Quantitative Imaging in Medicine and Surgery 2017

Journal: :TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A 2006

2014
Karin M. Andersson Anders Ahnesjö Christina Vallhagen Dahlgren

Metal objects in the body such as hip prostheses cause artifacts in CT images. When CT images degraded by artifacts are used for treatment planning of radiotherapy, the artifacts can yield inaccurate dose calculations and, for particle beams, erroneous penetration depths. A metal artifact reduction software (O-MAR) installed on a Philips Brilliance Big Bore CT has been tested for applications i...

2013
Abolfazl Mehranian Mohammad Reza Ay

X-ray computed tomography (CT) imaging of patients with metallic implants usually suffers from streaking metal artifacts. In this paper, we propose a new projection completion metal artifact reduction (MAR) algorithm by formulating the completion of missing projections as a regularized inverse problem in the wavelet domain. The Douglas-Rachford splitting (DRS) algorithm was used to iteratively ...

Journal: :Investigative radiology 2017
Lukas Filli Lukas Jud Roger Luechinger Daniel Nanz Gustav Andreisek Val M Runge Sebastian Kozerke Nadja A Farshad-Amacker

OBJECTIVE The aim of this study was to compare the degree of artifact reduction in magnetic resonance imaging achieved with slice encoding for metal artifact correction (SEMAC) in combination with view angle tilting (VAT) and multiacquisition variable resonance image combination (MAVRIC) for standard contrast weightings and different metallic materials. METHODS Four identically shaped rods ma...

2015
Michiro Susa Sota Oguro Kazutaka Kikuta Kazumasa Nishimoto Keisuke Horiuchi Masahiro Jinzaki Masaya Nakamura Morio Matsumoto Kazuhiro Chiba Hideo Morioka

BACKGROUND Standard imaging modality for the follow-up after prosthetic replacements for musculoskeletal tumor patients has been conventional radiography. This technique is effective in detecting subtle changes in bone adjacent to metal implants, but in many cases, radiographs do not lead to definitive diagnosis of postoperative adverse events such as acute infection, local recurrence of soft t...

Farahnaz Rahimi Sanaz Hariri Tabrizi, Zohreh Azma,

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید