Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography ...

M. Arash, M. Ghavami, M.S. Zakerhamidi, P. Mehnati,

Background: Bismuth composites are new and non-lead shields that are capable of breast dose reduction while preserving image quality. In this study, different percentages of Bismuth were used in designing and constructing polymer composites as breast shields in chest CT.  Materials and Methods: Micro particles of Bismuth with a ratio of 1% to 15% in Silicone matrix with two thicknesses were use...

Journal: :acta medica iranica 0
mohammad taghi bahreyni toossi medical physics research center, school of medicine, mashhad university of medical sciences, mashhad, iran. fateme akbari medical physics research center, school of medicine, mashhad university of medical sciences, mashhad, iran shahram bayani roodi medical physics research center, school of medicine, mashhad university of medical sciences, mashhad, iran.

nowadays, radiography is a necessary procedure in diagnosis and treatment of patients with dental problems. according to the alara (as low as reasonably achievable) principle, dentists must take radiographs of sufficient quality at the lowest possible radiation dose to the patients. the assessment of patient dose on panoramic radiography is difficult because of dynamic nature of the imaging pro...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2002
Vitaly Nag Sergey V Sholom Vadim V Chumak Marc F Desrosiers

A method for evaluating the overall uncertainty of alanine EPR transfer dosimetry in the therapeutic dose range is described. The method uses experimental data on EPR signal reproducibility from replicate dosimeters irradiated to low doses (1-5 Gy), estimates of Type B uncertainties, and Monte Carlo simulations of heteroscedastic orthogonal linear regression. A Bruker ECS106 spectrometer and Br...

2015
Shuhei Nomura Masaharu Tsubokura Ryugo Hayano Daisuke Yoneoka Akihiko Ozaki Yuki Shimada Tomoyuki Furutani Yukio Kanazawa Tomoyoshi Oikawa

OBJECTIVES To identify profiles of children who did not properly use individual radiation dosimeters following Japan's 2011 Fukushima nuclear incident, and to assess how much error is generated by improper dosimeter use. PARTICIPANTS The participants in this study comprised 1637 school children who participated in the external radiation exposure screening programme administrated by Minamisoma...

Journal: :Physics in medicine and biology 2007
Stephen Bosi Pourandokht Naseri Alicia Puran Justin Davies Clive Baldock

There is a need for stable gel materials for phantoms used to validate optical computerized tomography (CT) scanners used in conjunction with radiation-induced polymerizing gel dosimeters. Phantoms based on addition of light-absorbing dyes to gelatine to simulate gel dosimeters have been employed. However, to more accurately simulate polymerizing gels one requires phantoms that employ light-sca...

2012
Khalid A. Rabaeh Ahmed A. Basfar Akram A. Moussa

Nitro blue tetrazolium polyvinyl alcohol film dosimeters, NBT-PVA were prepared and evaluated based on radiation-induced reduction of NBT2þ . NBT-PVA film dosimeters containing different concentrations of NBT dye from 1 to 5 mM were prepared in a solution of ethanol. The dosimeters were irradiated with U-ray from Co source at doses up to 50 kGy. UV/vis spectrophotometer was used to investigate ...

Journal: :Medical physics 2012
S Akyalcin J English K Abramovitch J Rong

PURPOSE To directly measure skin dose using point-dosimeters from dental cone-beam CT (CBCT) scans. To compare the results among three different dental CBCT scanners and compare the CBCT results with those from a conventional panoramic and cephalomic dental imaging system. METHODS A head anthropomorphic phantom was used with nanoDOT dosimeters attached to specified anatomic landmarks of selec...

Journal: : 2022

The technology for construction and application of flexible dosimetric assemblies with LiF:Mg,Ti microcrystals (sizes about 0.1 mm) off-line measurements the spatial distribution absorbed dose inside organs at risk (rectum, urethra, vagina) high rate brachytherapy in oncoginecology has been developed. transfer from usage luminescent dosimeters macro sizes (more than 1 to microdosimetrs mm, comb...

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...