نتایج جستجو برای: load currents

تعداد نتایج: 197539  

2014
Abdel Aleem Abdel Hady

In power distribution networks, nonlinear loads produce harmonic currents that can pass through other sensitive locations in the power system and eventually back to the source. Harmonic currents can produce a variety of effects that are harmful to a power system structure. Consequentially, the deployment of new cost and energy efficient passive, active and hybrid filtering techniques is importa...

2009
Hulusi Karaca Ramazan Akkaya

Matrix converter is a single-stage converter which directly connects a three-phase voltage source to a three-phase load without dc-link components. Therefore, any harmonic distortion and imbalance in input voltage directly reflect to the output of the converter. Recently, many researchers have made an effort to cope with this problem. In this paper, under distorted input voltage conditions, beh...

2003
Metin Aydin Surong Huang Thomas A. Lipo

Performance evaluation of an axial flux surface mounted permanent magnet (PM) field controlled TORUS type (FCT) disc machine is presented in this paper. This new machine is an axial flux configuration with true field weakening capability since the flux is controlled by the DC field winding rather than opposing the magnets. Structure and operating principles are summarized in the first section. ...

2015
K. Elango

In distribution systems, sudden change in load draws non-sinusoidal currents and causes the load harmonics, excessive neutral currents creates disturbance and changes in Power factor. Static Synchronous Compensator (STATCOM) is used to provide reactive power to the transmission line. In this paper proposes with Fuzzy Logic Controller (FLC) to tune PI controller gain values under different opera...

2017
N. Chaitanya Chandra Sekhar

Received Apr 4, 2017 Revised May 9, 2017 Accepted Jun 30, 2017 This paper proposes a power management strategy of parallel inveters based system, to enhance the power generation capacity of the existing system with distributed energy sources one has to choose DG source based inverter connected in parallel with the existing system.Two DG sources PV, Fuel cells feeds the DC voltage to two paralle...

2011
K. Sravanthi

This paper presents the simulation of Shunt Active Power filter by using two different control schemes, indirect current control technique and ANN control technique. These two controle techniques are working under both balanced and unbalanced three phase voltage source conditions and it is feeding to a adjustable speed drive the torque speed characteristics of a motor is presented. Indirect cur...

Journal: :CoRR 2014
Mohammad Jamadi Farshad Merrikh-Bayat

This paper proposes an effective method for estimating the parameters of double-cage induction motors by using Artificial Bee Colony (ABC) algorithm. For this purpose the unknown parameters in the electrical model of asynchronous machine are calculated such that the sum of the square of differences between full load torques, starting torques, maximum torques, starting currents, full load curren...

2006
Jan B. Beck David C. Nemir

In most arc fault circuit breakers, arc detection is accomplished through the signature analysis of remotely sensed branch currents, with high frequency spectral components being indicative of arcing. This paper presents an alternative approach based upon system identification. A model is assumed for the load on the distribution bus. This model is updated continuously by comparing measured volt...

2013
Gokulananda Sahu Kamala Kanta Mahapatra Subrat Kumar Sahu

This paper investigates the design,analysis and simulation of a Distribution-STATic COMpensator(D-STATCOM) for non-linear load Composite(harmonic and reactive power) compensation on a three phase bus network. Composite compensation is achieved by implementation of a p-q controller, which monitors the load current and injects equal amplitude and opposite phase compensation currents to neutralize...

2016
M.Muthukumar T.Venkatesan

In modern power system, the switching devices are generally used in combination with unbalanced reactive loads which produces current related Power Quality (PQ) problems by making source currents distorted and unbalanced. Usually a STATCOM is installed to support electricity networks that have a poor power factor and often poor voltage regulation. A Distribution Static Compensator (DSTATCOM) op...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید