BACKGROUND Task group number 40 (TG-40) of the American Association of Physicists in Medicine (AAPM) has recommended calibration of any brachytherapy source before its clinical use. GZP6 afterloading brachytherapy unit is a (60)Co high dose rate (HDR) system recently being used in some of the Iranian radiotherapy centers. AIM In this study air kerma strength (AKS) of (60)Co source number thre...
PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...
Currently in the UK, shielding calculations for computed tomography (CT) systems are based on the BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) working group publication from 2000. Concerns have been raised internationally regarding the accuracy of the dose plots on which this method depends and the effect that new scanner technologies may have. A...
The specification of shielding for fluoroscopic facilities in the UK is based on the determination of scatter incident on a barrier using a simple formula linking kerma area product and scatter kerma. Over the last few years there has been a move to incorporate additional copper filtration in equipment used for high dose fluoroscopic and interventional examinations, and the existing formula doe...
A dosimetric procedure to assure the traceability to the air-kerma standard of the measurements performed in synchrotron radiation beams, was implemented at the “Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti” of ENEA (INMRI-ENEA). To this purpose, absolute air-kerma measurements by the ENEA standard free-air chamber for low energy x-rays have been performed at the SYRMEP (SYnchro...
Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area prod...
The aim of this study is to calculate the experimental and theoretical mass attenuation coefficient some Br compounds by using transmission method. Also these values were determined total electronic section, atomic effective number, electron density Kerma. We performed calculations in direct excitation geometry. cross sections halogene measured a narrow beam good geometry high resolution Si(Li)...
This study evaluated the performance of aluminum-copper alloy filtration, without the original aluminum filter, for dental radiography in terms of x-ray energy spectrum, air kerma rate and image quality. Comparisons of various thicknesses of aluminum-copper alloy in three different percentages were made with aluminum filtration. Tests were conducted on an intra-oral dental x-ray machine and wer...
A car-borne survey was carried out in Kerala, India to estimate external dose. Measurements were made with a 3-in × 3-in NaI(Tl) scintillation spectrometer from September 23 to 27, 2013. The routes were selected from 12 Panchayats in Karunagappally Taluk which were classified into high level, mid-level and low level high background radiation (HBR) areas. A heterogeneous distribution of air kerm...