نتایج جستجو برای: iridium_192 monte carlo mcnp

تعداد نتایج: 72882  

2015
Amaal A. Tawfik Moustafa Aziz

The dose distribution inside the Gamma Cobalt irradiation therapy unit at Egyptian Atomic Energy Authority (EAEA) was determined both experimentally and theoretically. MCNP computer code, based on Monte Carlo method, was used to model the unit and calculate the dose distributions in both normal and emergency situation of the unit. The dose distribution inside the unit was also measured during t...

A. Mostaar, M. Allahverdi, M. Shahriari,

Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran mehdi momen nezhad ph.d., linear accelerator dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran seyed mohammad hashemi m.sc., medical physics research center, mashhad university of medical sciences, mashhad, iran

introduction: in recent decades, several monte carlo codes have been introduced for research and medical applications. these methods provide both accurate and detailed calculation of particle transport from linear accelerators. the main drawback of monte carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

2012
Nam Zin Cho

Heat conduction [1] is usually modeled as a diffusion process embodied in heat conduction equation. The traditional numerical methods [2, 3] for heat conduction problems such as the finite difference or finite element are well developed. However, these methods are based on discretized mesh systems, thus they are inherently limited in the geometry treatment. This chapter describes the Monte Carl...

2007
D. V. Fedorchenko

Design and maintenance of nuclear cycle facilities mandatory imply implementation of efficient radiation protection. Radiation environment assessment and shielding optimization require a considerable amount of numerical calculations. Nowadays mathematical modelling methods and corresponding software are widely used for such kind of problems. All the software used for radiation fields modelling ...

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

آقامیری, سید محمود رضا, باغانی, حمیدرضا, حیدرلو, نعمت‌الله, مهدوی, سید ربیع,

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

Journal: :iranian journal of radiation research 0
a.s. meigooni university of kentucky medical center, department of radiation medicine, lexington, kentucky, usa u. malik h. zhang s.a. dini n. j. meigooni k. komanduri

background: an effective method for management of large and bulky malignant tumors. this treatment modality is also known as specially fractionated radiation therapy (sfrt). in this treatment technique a grid block converted the open radiation field into a series of pencil beams. dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and mo...

2004
J. Boson G. Ågren L. Johansson K. Lidström T. Nylén

Calibrations of an HPGe detector were made with respect to photon energy and angle of incidence for the use in field gamma spectrometry. The same detector was modelled in MCNP4C and simulated. This revealed some significant differences between the theoretical (simulated) efficiency and the measured efficiency of the detector, especially at lower energies. In order to investigate the reason for ...

Journal: :MRS Advances 2023

Abstract The contents and distribution of radionuclides in activated metallic wastes are major concerns while designing a leaching model safety case. This study investigated 60 Co as typical activation product the lower tie plate (i.e., stainless steel endpiece BWR fuel assembly) irradiated for 35.0 GWd/tHM burnup, using imaging (IP) method. calculations coupled with Monte Carlo burnup neutron ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید