نتایج جستجو برای: ion selective membrane
تعداد نتایج: 751523 فیلتر نتایج به سال:
A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....
a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...
a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m with nernstian slope of 19.64 ± 0.15 mv decade-1...
A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M with Nernstian slope of 19...
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
a pvc membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(iii) ion was prepared. this electrode revealedsuch a good selectivity toward la3+ ion over a wide variety of other metal ions. some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید